Code
Problem Description
Troubleshooting
5405500
Error occurred by the
Transport Path on the GS005
during Deposit Cancel.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5405600
Error occurred by the
Transport Path on the GS006
during Deposit Cancel.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the cassette not received(9)
4. Remove substance in the Rear
Transport Path(7)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance.
5405A00
Error occurred by the
Transport Path on the GS021
during Deposit Cancel.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5405B00
Error occurred by the
Transport Path on the GS022
during Deposit Cancel.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the banknotes and the
foreign substance from the reject
cassette (19)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5405G00
Error occurred by the
Transport Path on the GS614
during Deposit Cancel.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5405H00
Error occurred by the
Transport Path on the GS618
during Deposit Cancel.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5405J00
Error occurred by the
Transport Path on the GS619
during Deposit Cancel.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance