Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-39
Code
Problem Description
Troubleshooting
5207A00
Error occurred by the notes
disorder on the GS021 during
Deposit Count.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207B00
Error occurred by the notes
disorder on the GS022 during
Deposit Count.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the banknotes and the
foreign substance from the reject
cassette (19)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207G00
Error occurred by the notes
disorder on the GS0614 during
Deposit Count.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207H00
Error occurred by the notes
disorder on the GS618 during
Deposit Count.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207J00
Error occurred by the notes
disorder on the GS619 during
Deposit Count.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207K00
Error occurred by the notes
disorder on the GS703 during
Deposit Count.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5207M00
Error occurred by the notes
disorder on the GS031 during
Deposit Count.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13~20)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5207N00
Error occurred by the notes
disorder on the GS032 during
Deposit Count.
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13~20)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance