Chapter5. Coin Dispenser Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
5-1
Chapter5. Coin Recycler
Code
Problem Description
Troubleshooting
RFFDN
Fail to Polling and Open.
Check USB Cable connection state.
R3803
Supply current outside operating
limits : Solenoid rail
Check supply power status.
R3802
Supply current outside operating
limits : Hopper rail
Check supply power statsu.
R3801
Supply current outside operating
limits : +5V rail
Check Supply powr status.
R3701
Initialisation error : Singulator flush
timeout
1. Device Power OFF and ON
2. Execute Initialize.
R360C
Firmware error : Stack overflow
Update Firmware .
R360B
Firmware error : Error during
upgrade
Update Firmware.
R360A
Firmware error : Program
checksum error
Update Firmware .
R3609
Firmware error : Bad double bowl
hopper config
Change hopper config.
R3608
Firmware error : Coin acceptor
programming error
Update Coin acceptor Firmware.
R3607
Firmware error : Unhandled Coin
acceptor event
Update Coin acceptor Firmware.
R3606
Firmware error : Coin acceptor
bad build
Update Coin acceptor Firmware.
R3605
Firmware error : Hopper bad build
ID
Update Hopper Firmware.
R3604
Firmware error : Hopper firmware
too old
Update Hopper Firmware
R3603
Firmware error : Hopper bad
firmware ID
Update Hopper Firmware.
R3602
Firmware error : Coin acceptor
firmware too old
Update Coin acceptor Firmware .
R3601
Firmware error : Coin acceptor
firmware ID
1. Device Power OFF and ON
2. Execute Initialize.
R3501
RTC fault : Read/Write fail
1. Device Power OFF and ON
2. Execute Initialize.
R3303
Door open : Carousel lid
Check Carousel lid status
R3301
Door open : Singulator door
Check Singulator door status.
R3200
Battery fault : Battery flat, missing
or over-voltag
Check Battery status
R310A
Fault on opto sensor : Coin
acceptor park opto
Check Coin acceptor park opto status.
R3109
Fault on opto sensor : Coin
acceptor diameter opto
Check Coin acceptor diameter opto
status.
R3108
Fault on opto sensor : Carousel
pusher opto crdit sensor
Check Carousel pusher opto crdit
sensor status
R3107
Fault on opto sensor : Carousel
track opto
Check Carousel track status
R3106
Fault on opto sensor : Cahsbox
flap
Check Cahsbox flap Status
R3105
Fault on opto sensor : Accept flap
Check Accept flap status