![background image](http://html1.mh-extra.com/html/nautilus-hyosung/mx8800/mx8800_manual_3517484098.webp)
Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-94
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
535GC00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Deposit End.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
535GG00
Encoder Sensor(GS513) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS513 works fine if
there is nothing jammed.
535GH00
Encoder Sensor(GS513) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS513 works fine if
there is nothing jammed.
535J300
Failure to RC5 full check
during Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Check the stage status after open the
recycle cassette(E)
5. Check contamination status of the
GS512 sensor.
535R100
RC5 message timeout error
during operation ready in the
Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
535R200
RC5 message timeout error
during transation operation in
the Deposit End .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
535R300
RC5 message timeout error
during postprocessing of
Deposit End Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
535S100
Undefined return value of RC5
during Deposit End.
1. Operate to initialize BRM(Recovery)
535S200
Undefined command of RC5
during Deposit End.
1. Operate to initialize BRM(Recovery)
536R100
CSM message timeout error
during operation ready in the
Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
536R200
CSM message timeout error
during transaction operation in
the Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization