Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-27
Code
Problem Description
Troubleshooting
I1886
[Initialize] A customer gets notes
while retracting those (subnormal).
1. Check the residual media at the
Bundle part (1).
2. Check whether sensors (BDS01,
BDS02, BDS05, BDS07) checking
residual media in the Bundle(1) are
polluted.
3. Execute CCIM initialization.
I1887
[Initialize] A customer gets notes
before retracting those
(subnormal).
1. Check the residual media at the
Bundle part (1).
2. Check whether sensors (BDS01,
BDS02, BDS05, BDS07) checking
residual media in the Bundle(1) are
polluted.
3. Execute CCIM initialization.
I1888
[Initialize] A customer gets notes
while retracting those (subnormal).
1. Check the residual media at the
Bundle part (1).
2. Check whether sensors (BDS01,
BDS02, BDS05, BDS07) checking
residual media in the Bundle(1) are
polluted.
3. Execute CCIM initialization.
I1893
[Initialize]Failure to check the last
note at the termination of mid
transport path while retracting
those.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I18A0
[Initialize]Failure to check Motor
Fuse in CCIM main board(ESM01)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18A1
[Initialize]Failure to check Motor
Fuse in CCIM main board(RJM02)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18A2
[Initialize]Failure to check Motor
Fuse in CCIM main
board(BDM03)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18A3
[Initialize]Failure to check Motor
Fuse in CCIM main
board(BDM04)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18A4
[Initialize]Failure to check Motor
Fuse in CCIM main
board(BDM05)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18A5
[Initialize]Failure to check Motor
Fuse in CCIM main board(FDM01)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18A6
[Initialize]Failure to check Motor
Fuse in CCIM main board(FDM02)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18A7
[Initialize]Failure to check Motor
Fuse in CCIM main board(FDM03)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.
I18A8
[Initialize]Failure to check Motor
Fuse in CCIM main
board(NCM01)
1. Execute CCIM initialization.
2. Change the CCIM Unit or Board when
the same error occurs after initialization.