Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-371
Code
Problem Description
Troubleshooting
5D00200
GS002 light jam error during
Initialize .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Rotate the knob of the Front
Transport Path(4)
5. Remove the Jam between BC(5) and
Front Transport Path(4).
5D00300
GS003 light jam error during
Initialize .
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the Rear Transport Path(6)
4. Remove the Jam between Rear
Transport Path(11) and Rear Transport
Path(6).
5D00400
GS004 light jam error during
Initialize .
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the cassette not received(9)
4. Remove the Jam between Rear
Transport Path(8) and Rear Transport
Path(11).
5D00500
GS005 light jam error during
Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the Jam between TE(12)
and Rear Transport Path(11).
5D00600
GS006 light jam error during
Initialize.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove the cassette not received(9)
4. Remove the Jam between Rear
Transport Path(7) and Rear Transport
Path(11).
5D00A00
GS021 light jam error during
Initialize.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Rotate the knob of the Rear Transport
Path(4)
5. Remove notes in BC
5D00B00
GS022 light jam error during
Initialize.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove the Jam on the Mid
Transport Path(13).
5D00G00
GS614 light jam error during
Initialize.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove Jam between the CSM(3)
and the Rear Transport Path(11).
5D00H00
GS618 light jam error during
Initialize.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove Jam in the Rear Transport
Path(11).