Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-492
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5PBH700
RC2 EEPROM write error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5PBH800
RC3 EEPROM write error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5PBH900
RC4 EEPROM write error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5PBHA00
RC5 EEPROM write error
during CST notes count
Detete.
1. Check the RC Connector
2. Reload the RC after removing RC
3. Replace the RC if same error occures
during initialization
5PBHB00
RC1 EEPROM data verify
error when CST notes count
Detete.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5PBHC00
RC2 EEPROM data verify
error when CST notes count
Detete.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5PBHD00
RC3 EEPROM data verify
error when CST notes count
Detete.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5PBHE00
RC4 EEPROM data verify
error when CST notes count
Detete.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5PBHF00
RC5 EEPROM data verify
error when CST notes count
Detete.
1. Reload the RC after removing RC
2. Replace the RC if same error occures
during initialization
5PBHG00
No detect when RC EEPROM
R/W inter lock during CST
notes count Detete.
1. Check the lower unit status of inter
lock
2. Exchange or clean the inter lock
sensor if occur same error
5PBS000
RBU communication timeout
error when Read Initial Info.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5PBS100
RBU connection sequence
error when Read Initial Info.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5PBS200
RBU connection MI error
during when Read Initial Info.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5PUS100
USB sequence number
duplicate when Read Initial
Info.
1. Restart over AP-SP
5PUS300
USB command data length
error when Read Initial Info.
1. Check USB connection
2. Operate to initialize BRM(Recovery)
5Q0G100
Failure to 3 Way Gate 0
degree mode conversion
during Retract CSM + TE.
1. Open the upper unit
2. Open the CSM and TE(12)
3. Remove notes and substance from
the gate in the Rear Transport Path