Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-456
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
5K1G100
Failure of return notes to RC1
during Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Remove notes and substance using
jam removal Knob in the upper side
6. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K1G200
Failure to move stack position
of RC1 PP during Withdrawal
Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Open the recycle cassette door(A)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
5K1G400
Failure to upword moving of
PP during RC1 stack roller
retreat movement in the
Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Open the recycle cassette door(A)
5. Check cassette status to move stage
up and down
6. Check the lower edge of the
door´s right side(Key part) if you
don´t find any problem
5K1G500
Failure of RC1 stack roller
retreat during Withdrawal
Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the jam removal knob rotates
softly
5K1G600
Exceeds retry count limit of
detecting RC1 stack
roller´s falling back and
avoiding during Withdrawal
Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the jam removal knob rotates
softly
5K1G800
RC1 Push pressure Movement
error during Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Put down the Stage after open the
recycle cassette door (A)
5. Check the upper side of the recycle
cassette
5K1GA00
RC1 solenoid echo error duing
Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette(A) and
reload
4. Replace the cassette when same
error occurs