Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-397
Code
Problem Description
Troubleshooting
5D2GF00
Detect both GS208(separate
pressure) and GS212(Bottom)
as excessive note durting
Initialize
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Put down the Stage after open the
recycle cassette door (B)
5. Remove note.
5D2GG00
Encoder Sensor(GS213) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Initialize.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS213 works fine if
there is nothing jammed.
5D2GH00
Encoder Sensor(GS213) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Initialize.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS213 works fine if
there is nothing jammed.
5D2J300
RC2 full check failure during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Check the stage status after open the
recycle cassette(B)
5. Check contamination of GS212
sensor.
5D2R100
RC2 message timeout error
during operation ready in the
Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D2R200
RC2 message timeout error
during transaction operation in
the Initialize.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D2R300
RC2 message timeout error
during postprocessing to
Initialize error .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5D2S100
Undefined return value of RC2
during Initialize.
1. Operate to initialize BRM(Recovery)
5D2S200
Undefined command of RC2
during Initialize.
1. Operate to initialize BRM(Recovery)
5D30500
GS305 Light Jam during
Initialize.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(16)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).