Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-355
Code
Problem Description
Troubleshooting
5B72800
Error occurred by the notes
remained on the GS709 during
Retract TE.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Rotate a knob of TE(12)
4. Remove notes and substance in the
Rear Transport Path(11)
5B7G100
Motor stack direction operation
disorder during Retract TE.
1. Open the upper unit
2. Confirm to Rotate a knob of TE(12)
softly
5B7G200
Motor separate direction
operation disorder during
during Retract TE.
1. Open the upper unit
2. Confirm to Rotate a knob of TE(12)
softly
5B7G300
Motor stop disorder during
Retract TE.
1. Open the upper unit
2. Confirm to Rotate a knob of TE(12)
softly
5B7G400
No detect the front end of tape
during Retract TE.
1.Open upper Unit
2. Check the notes remain in the TE(12)
3. Check the color of tape´s front
end is black in the TE(12)
4. Remove notes remain in the TE
5B7G500
Detect the front end of tape
during Retract TE.
1.Open upper Unit
2. Check the notes remain in the TE(12)
3. Check the color of tape´s front
end is black in the TE(12)
4. Remove notes remain in the TE
5B7G600
No detect the rear end of tape
during Retract TE.
1.Open upper Unit
2. Check the notes remain in the TE(12)
3. Cheeck whether black tape is wrap
with a drum in the TE(12)
4. Remove notes remain in the TE
5B7G700
Detect the rear end of tape
during Retract TE.
1.Open upper Unit
2. Check the notes remain in the TE(12)
3. Cheeck whether black tape is wrap
with a drum in the TE(12)
4. Remove notes remain in the TE
5B7J100
TE drum full during Retract TE. 1. Open the upper unit
2. Check the notes remain in the TE(12)
3. Remove notes remain in the TE
5B7J200
TE drum empty during Retract
TE.
1. Open the upper unit
2. Check the notes remain in the TE(12)
3. Check the GS701/GS702/GS709
Sensor
4. Remove notes remain in the TE
5B7J300
Normal Receipt End is not
possible during Retract TE.
1. Operate to initialize BRM(Recovery)
5B7R100
TE message timeout error
during operation ready in the
Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5B7R200
TE message timeout error
during transaction operation in
the Retract TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization