Code
Problem Description
Troubleshooting
5K07500
Error occurred by the notes
disorder on the GS005 during
Withdrawal Reject.
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K07600
Error occurred by the notes
disorder on the GS006 during
Withdrawal Reject .
1. Open the upper unit
2. Open the TE(Temporary Escrow) (12)
3. Open the cassette not received(9)
4. Remove notes and substance in the
Rear Transport Path(7)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K07A00
Error occurred by the notes
disorder on the GS021 during
Withdrawal Reject .
1. Open the lower unit
2. Remove notes and substance in the
Mid Transport Path(13)
3. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K07B00
Error occurred by the notes
disorder on the GS022 during
Withdrawal Reject .
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the banknotes and the
foreign substance from the reject
cassette (19)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K07G00
Error occurred by the notes
disorder on the GS614 during
Withdrawal Reject .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
CSM(3)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K07H00
Error occurred by the notes
disorder on the GS618 during
Withdrawal Reject .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5K07J00
Error occurred by the notes
disorder on the GS619 during
Withdrawal Reject .
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Remove notes and substance in the
Rear Transport Path(11)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance