Page 1: ...NP 800S RISC based operator interface terminal with 7 7 flat panel display User s Manual ...

Page 2: ...fety Guidelines 11 2 3 Communications Connections 13 2 3 1 Connector COM 1 RS232 13 2 3 2 Connector COM2 RS232 14 2 3 3 Connector COM3 RS485 14 2 3 4 USB Client port 15 2 3 5 USB Master port Error Bookmark not defined 2 3 4 Dip Switch 16 2 4 CE Requirements 17 2 5 Dimensions of NP 800S 18 Chapter 3 Windows CE NET 20 3 1 Introduction 20 3 2 Utilities 20 3 2 1 Soft Keyboard 20 3 2 2 System Settings ...

Page 3: ...3 3 4 Application program development 28 3 4 1 Microsoft eMbedded Visual C 4 0 28 3 4 2 NP 800S SDK 29 ...

Page 4: ... thus subject to change without notice No part of this manual may be reproduced copied translated or transmitted in any form or by any means without the prior written permission of IVC Displays Inc Information provided in this manual is intended to be accurate and reliable However IVC Displays Inc assumes no responsibility for its use nor for any infringements upon the rights of third parties whic...

Page 5: ...amage to equipment with the symbol shown to the left A Warning symbol indicates that the reader should pay special attention to the accompanying text Precautionary steps should be taken to insure that the installation is in compliance with warnings Warnings include hazardous conditions that could cause personal injury or equipment damage if care is not taken The text next to this symbol describes ...

Page 6: ...s bundled with Windows CE OS The built in Windows CE OS platform forms a bridge that lets NP 800S be an open HMI solution for system integration Features Built in flash memory and Windows CE OS inside All in one platform the CPU DRAM and Windows CE are integrated Low power consumption and Fan less NEMA 4 IP65 compliant front panel One CompactFlash slot Audio Ethernet port 10 100Base T 1 2 Specific...

Page 7: ... 50 T B R L Luminance cd m2 150 Storage temperature C 20 60 Operating temperature C 0 45 Backlight CCFLx2 Contrast ratio 30 1 Touch screen Type 4 wire analog resistive Resolution continuous Light transmission above 80 Life 1 million activation minimal Environmental Specifications Operating temperature 0 45 C 32 113 F Relative humidity 10 90 40 C non condensing Shock operation 10 to 25Hz X Y Z dire...

Page 8: ...els with a depth of 4 105mm It is recommended that the unit be mounted on the front panel of a steel enclosure through an appropriate opening Allow a clearance of 1 25mm around the sides of the unit for mounting hardware Allow clearance for cable connections to the back of the unit Unit depth may vary according to cable type used Typically plan a depth to accommodate at least 4 105mm behind the pa...

Page 9: ...ses vapors or dusts The unit should not be installed where fast temperature variations and or high humidity are present This will cause condensation of water in the device Do not install these terminals in environments where have inflammable gases 2 2 Power Connections Make sure that all local and national electrical standards are met when the installing the unit Contact your local authorities to ...

Page 10: ...ions Caution Supply Voltage Condition Do not power the NP 800S and inductive DC loads or input circuitry to the controller with the same power supply Note The 24 VDC output from some controllers may not have enough current to power the NP 800S Caution Wire Routing Wire lengths should be minimized Maximum 1600 500 m shielded 1000 300 m unshielded Wires should be run in pairs with a neutral or commo...

Page 11: ...d be connected to a tree from a central star earth ground point This ensures that no ground conductor carries current from any other branch 2 2 3 CE Requirements To make an NP 800S comply with EMC directives and to reduce susceptibility to electrical interference a separate 14 AWG ground wire should be taken to the chassis ground terminal of the power connector This ground connection should be run...

Page 12: ...personnel ICS 3 304 81 Safety Recommendations Consideration should be given to the use of an emergency stop function which is independent of the programmable controller Where the operator is exposed to the machinery such as in loading or unloading a machine tool or where the machine cycles automatically consideration should be given to the use of an electromechanical override or other redundant me...

Page 13: ...ach communication Shielded cable must be used for long lengths or cables run in an electrically noisy environment Do not run cables next to AC power lines or near sources of electrical noise Be sure that the cable ends have been inserted all of the way into mating connectors and are secure 2 3 1 Connector COM 1 RS232 Pin Designations COM1 RS 232 Pin assignment of the 9 Pin Male SUB D COM1 RS 232 P...

Page 14: ...4 5 GND Signal Ground 6 7 RTS Ready to send output 8 CTS Clear to send input 9 Pin 1 6 8 is short 2 3 3 Connector COM3 RS485 Pin Designations COM3 RS 485 Pin assignment of the 9 Pin Female SUB D COM3 RS 485 Port Pin Symbol RS 485 4wire RS 485 2wire 1 2 Tx Transmitted Data Data 3 Tx Transmitted Data Data 4 Rx Received Data 5 Rx Received Data 6 GND Signal Ground Signal Ground 7 8 9 ...

Page 15: ... NP 800S COM3 RS 485 9P D SUB Female RS 485 4 wire Device 2 Tx Tx RS485 Transmit 3 Tx Tx RS485 Transmit 4 Rx Rx RS485 Receive 5 Rx Rx RS485 Receive 6 GND 2 3 4 USB Client port The USB client port for ActiveSync use a USB client to USB host cable connects the USB client port on NP 800S and the USB host port on user s host PC Pin Function 1 N C 2 USB_DATA 3 USB_DATA 4 GND ...

Page 16: ...to upper left lower left lower right and upper right corners When all five are done the will disappear The Touch Screen parameter will store at Flash Rom Boot Loader mode Load new Windows CE image file If the NP 800S already load the CE image with boot loader Set the DIP SW2 ON then power ON into boot loader mode Refer the load Win CE image document Pin1 Pin2 Mode OFF OFF Normal ON OFF Touch Scree...

Page 17: ...atisfactorily in electromagnetic noise immunity and without emitting high levels of electrical noise into the environment emission The units are designed to meet European Community standards when installed per the wiring instructions in this manual Compatibility Standards The NP 800S has been designed to meet electromagnetic compatibility for industrial environments CISPR EN 55011 Group 1 Class A ...

Page 18: ...18 2 5 Dimensions of NP 800S Cutout dimensions NP 800S 222mm 8 74 W x 167mm 6 57 H Side View Front View Bottom View ...

Page 19: ...mpactFlash slot b Sound ports i Com1 RS232 c MIC ports j Com2 RS232 d Ethernet port RJ 45 k Com3 RS485 e Fuse l Dip Switch f Power connector m Contrast Adjust VR g USB client Rear View k j i d e f l m g b c a ...

Page 20: ...eneration of smart mobile and small footprint devices With a complete operating system feature set and end to end development environment Windows CE NET contains everything you need to create a custom Windows CE based device that requires rich networking hard real time and a small footprint as well as rich multimedia and Web browsing capabilities 3 2 Utilities There are several useful utilities bu...

Page 21: ...us bar Tap this icon by the stylus to activate hide this Soft keyboard 3 2 2 System Settings MT606 provides an integrated utility for users to make basic setting of the machine Step 1 Tap the cecp icon from Desktop 2 Launch the System Settings Control Panel Touch Screen settings The touch screen calibration can be executed from the Control Panel Step 1 Launch the System Settings Control Panel ...

Page 22: ...page of the cecp provides the function to turn off the LCD backlight and thus elongates the period of service For example if the user wants the backlight turned off automatically after 10 minutes when the device was no longer used The user must select 10 minutes in the put down box and then press OK button Then the screen save function is enabled Once the backlight was turned off events or perturb...

Page 23: ...t Storage Manager The IPSM serves as a small capacity hard disk You can store your data and application in the Flash ROM via IPSM function to prevent unexpected loss of data as power failure When power is shutdown and cold boot the data in the Flash ROM area would be saved 3 2 4 Startup After the system boot up the startup execution function would automatically perform This function is useful for ...

Page 24: ...ber of ASCII characters after pound sign command line optional parameters For example to start MyApp exe and pass two optional parameters into the application a sample MyApp lnk file contains the following 40 Windows MyApp exe parameter1 parameter2 3 2 5 Remote Desktop Connection Use Remote Desktop Connection you can remotely control your computer To use Remote Desktop you need the following Windo...

Page 25: ...log box type your user name password and domain if required and then click OK The Remote Desktop window will open and you will see the desktop settings files and programs that are on your office computer Your office computer will remain locked Nobody will be able to work at your office computer without a password nor will anyone see the work you are doing on your office computer remotely Note To c...

Page 26: ... up Connections 3 Find the default device name Change it to a unique one depending on the plan of individual LANs LAN90001 4 If the NP 800S is a node of a LAN with DHCP servers it is now available 5 If the NP 800S is a node of a LAN with fixed IP server please consult with MIS to get specific IP address Click Start Settings Control Panel Double click Network and Dial up Connections and update the ...

Page 27: ... CE boot up don t connect the USB cable 3 Connect the USB client port of the NP 800S and the USB host port of the host PC by the USB client to USB host cable 4 When the Add New Hardware Wizard asks for the driver click Browse and select the file named wceusbsh inf under the USB driver directory 5 Run NP 800S Windows repllog exe 6 Follow the onscreen instructions to establish a partnership and sync...

Page 28: ...Windows CE application programs are only portable in the source code level Users must rebuild the runtime file for a different Windows CE platform even though the source code may not be changed at all The following development tools must be installed on the PC Microsoft eMbedded Visual C 4 0 Microsoft eMbedded Visual C 4 0 Service Pack 1 NP 800S SDK 3 4 1 Microsoft eMbedded Visual C 4 0 System Req...

Page 29: ... an extensive set of functions that are specific to the MT606 hardware Step Installing the NP 800S SDK 1 Download or from NP 800S SDK CD find the HMI_MT_608_SDK msi file Double click the file s name start the Setup Wizard 2 The installer will be prompted for acceptance of a license agreement Following that the SDK should install itself automatically on the host machine without further operator int...

Page 30: ...30 ...