Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-473
Code
Problem Description
Troubleshooting
5K5GB00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
5K5GC00
Encoder Sensor(GS507) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS507 works fine if
there is nothing jammed.
5K5GG00
Encoder Sensor(GS513) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS513 works fine if
there is nothing jammed.
5K5GH00
Encoder Sensor(GS513) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Withdrawal Reject.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS513 works fine if
there is nothing jammed.
5K5J300
Failure to RC5 full check
during Withdrawal Reject.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (A)
4. Check the stage status after open the
recycle cassette(A)
5. Check contamination of sensor
GS112
5K5R100
RC5 message timeout error
during operation ready in the
Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5K5R200
RC5 message timeout error
during transation operation in
the Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5K5R300
RC5 message timeout error
during postprocessing of
Withdrawal Reject Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5K5S100
Undefined return value of RC5
during Withdrawal Reject.
1. Operate to initialize BRM(Recovery)
5K5S200
Undefined command of RC5
during Withdrawal Reject.
1. Operate to initialize BRM(Recovery)