Error Code List Chapter4. Cash & Check In Module
4-36
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
I1D01
[Initialize]Error occurred by the
notes disorder on the FDS01
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1D02
[Initialize]Error occurred by the
notes disorder on the FDS02
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1D03
[Initialize]Error occurred by the
notes disorder on the FDS03
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1D04
[Initialize]Error occurred by the
notes disorder on the FDS04
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1D05
[Initialize]Error occurred by the
notes disorder on the FDS05
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1D06
[Initialize]Error occurred by the
notes disorder on the
FDS03,FDS04
1. SCM(2) Open
2. Remove the notes and alien materials
in the SCM. and Bundle.
I1D07
[Initialize]Error occurred by the
notes disorder on the BCS01
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I1D08
[Initialize]Error occurred by the
notes disorder on the BCS02
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I1D09
[Initialize]Error occurred by the
notes disorder on the
BCS01,BCS02
1. Open the BC cover(3) and remove the
residual media and alien materials.
2. Check the BC Lock state.
I1D0A
[Initialize]Error occurred by the
notes disorder on the FDS15
1. Open the BM4 moving path and then
remove the residual media and alien
materials.
I1D0B
[Initialize]Error occurred by the
notes disorder on the AAS06
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I1D0C
[Initialize]Error occurred by the
notes disorder on the AAS05
1. After opening the BM2(7) moving
path, open the Alignment(4) Guide2 to
remove media and alien materials.
2. Initialize the device.
4. If the same fault continuously occurs
after checking the device, replace the
Alignment(4) Module.
I1D0D
[Initialize]Error occurred by the
notes disorder on the AAS03
1. Open the alignment(4) cover and
remove the residual media and alien
materials.
2. Initialize the device.
3. Check the alignment(4) cover lock
state.
I1D0E
[Initialize]Error occurred by the
notes disorder on the RCS01
1. Remove the internal media and alien
materials in the Recognition(5).
2. Initialize the device.
3. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.