Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-82
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
532GC00
Encoder Sensor(GS207) for
Feed Motor failed to detect
Dark status when Feed Motor
runs in stacking direction
during Deposit End.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS207 works fine if
there is nothing jammed.
532GG00
Encoder Sensor(GS213) for
Stack Roller failed to detect
Dark status when Feed Motor
runs in stacking direction
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS213 works fine if
there is nothing jammed.
532GH00
Encoder Sensor(GS213) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Deposit Ready.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #2 and
open its door.(B)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS213 works fine if
there is nothing jammed.
532J300
Failure to RC2 full check
during Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (B)
4. Check the stage status after open the
recycle cassette(B)
5. Check contamination of GS212
sensor.
532R100
RC2 message timeout error
during operation ready in the
Deposit End.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
532R200
RC2 message timeout error
during transation operation in
the Deposit End .
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
532R300
RC2 message timeout error
during postprocessing of
Deposit End Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
532S100
Undefined return value of RC2
during Deposit End.
1. Operate to initialize BRM(Recovery)
532S200
Undefined command of RC2
during Deposit End.
1. Operate to initialize BRM(Recovery)
5330500
GS305 Light Jam during
Deposit End.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the Jam on the recycle
cassette(16)
4. Rotate the knob of the Mid Transport
Path
5. Remove the Jam on the Mid
Transport Path(13).