Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-274
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
595GH00
Encoder Sensor(GS513) for
Stack Roller failed to detect
Light status when Feed Motor
runs in stacking direction
during Customer Change.
1. Open the lower unit.
2. Open the Mid Transport Path.
3. Take out the recycle cassette #5 and
open its door.(E)
4. Remove jammed notes or substance
using any wheels on the upper side.
5. See whether GS513 works fine if
there is nothing jammed.
595J300
RC5 full check failure during
Customer Change.
1. Open the lower unit
2. Open the Mid Transport Path
3. Remove the recycle cassette (E)
4. Check the stage status after open the
recycle cassette(E)
5. Check contamination status of the
GS512 sensor.
595R100
RC5 message timeout error
during Customer Change
ready.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
595R200
RC5 message timeout error
during Customer Change
transaction.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
595R300
RC5 message timeout error
during postprocessing to
Customer Change error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
595S100
Undefined Return Values of
RC5 during Customer Change.
1. Operate to initialize BRM(Recovery)
595S200
RC5 undifined command
during Customer Change.
1. Operate to initialize BRM(Recovery)
5962100
Error occurred by the notes
remained in CSM during
Customer Change.
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5962400
undifined CSM Command error
during Customer Change.
1. Operate to initialize BRM(Recovery)
596B100
Error of receiving notes and
position of notes during
Customer Change.
1. Open the upper unit
2. Open the CSM(1)
3. Remove notes and substance in the
CSM(1)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
596G100
BP stack position movement
error during Customer Change.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM
596G200
BP notes out error during
Customer Change.
1. Open the upper unit
2. Open the CSM(1) shetter
3. Check the notes and substance
inside of the CSM