Chapter4. Cash & Check In Module Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
4-111
Code
Problem Description
Troubleshooting
I4703
[Deposit Count/Check]MICR force
shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4704
[Deposit Count/Check]Fault of
calling a undefined command from
MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4705
[Deposit Count/Check]RCS02
Dark is not detected when Moving
Header is moving to H.P.
1. Check MICR RCM01 Motor(5)
operation and alien materials.
2. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I4706
[Deposit Count/Check]RCS02
Dark is not detected when Moving
Header is moving to H.P.
1. Check MICR RCM01 Motor(5)
operation and alien materials.
2. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I4707
[Deposit Count/Check]RCS02
Light is not detected while
initializing MICR.
1. Check MICR RCM01 Motor(5)
operation and alien materials.
2. Check the cable connected to Moving
Header home position(RCS02) sensor.
3. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I4708
[Deposit Count/Check]The first
motor is stopped after running and
timeout occurs while initializing
MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4709
[Deposit Count/Check]The second
motor is stopped after running and
timeout occurs while initializing
MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I470A
[Deposit Count/Check]The third
motor is stopped after running and
timeout occurs while initializing
MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I470B
[Deposit Count/Check]Jam occurs
at the Recog entry sensor
(RCS01) when executing MICR.
1. Remove the internal media and alien
materials in the Recognition(5).
2. If the same fault continuously occurs
after checking the device, replace the
Recognition(5) Module.
I470C
[Deposit Count/Check]MICR read
timeout when executing MICR.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4801
[Deposit Count/Check] A
command was not executed due
to a fault which has occurred while
preparing the main task.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4802
[Deposit Count/Check]Main task
force shutdown.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.
I4803
[Deposit Count/Check] Receives a
command which has not been
defined in the main task.
1. Execute CCIM initialization.
2. Reboot the system when the same
error occurs after initialization.