Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-505
Code
Problem Description
Troubleshooting
5Q6P300
PP separate position
movement error during Retract
CSM + TE.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5Q6P400
PP lose return position
movement error during Retract
CSM + TE.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5Q6P500
PP notes out position
movement error during Retract
CSM + TE.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5Q6P600
PP notes alignment error
during Retract CSM + TE.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5Q6P700
PP separate control(during
separating) error during
Retract CSM + TE.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5Q6P800
PP stack control(during
stacking) error during Retract
CSM + TE.
1. Open the upper unit
2. Check the notes and substance
inside of the CSM
3. Check PP rotates softly using knob of
the CSM(1)
5Q6P900
Error of reverting notes during
Retract CSM + TE.
1. Open the upper unit
2. Check the notes and substance in the
CSM(2)
3. Check the knob rotates softly in the
CSM(2)
4. Check the knob rotates softly in the
CSM(3)
5Q6R100
CSM message timeout error
during operation ready in the
Retract CSM + TE.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q6R300
CSM message timeout error
during postprocessing to
Retract CSM + TE Error.
1. Operate to initialize BRM(Recovery)
2. Reboot the system when same error
occurred (message timeout error) after
initialization
5Q7G100
Motor stack direction operation
disorder during Retract CSM +
TE.
1. Open the upper unit
2. Confirm to Rotate a knob of TE(12)
softly
5Q7G200
Motor separate direction
operation disorder during
during Retract CSM + TE.
1. Open the upper unit
2. Confirm to Rotate a knob of TE(12)
softly
5Q7G300
Motor stop disorder during
Retract CSM + TE.
1. Open the upper unit
2. Confirm to Rotate a knob of TE(12)
softly