Error Code Manual Chapter2. Bill Recycling Machine (BRM)
2-546
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
Code
Problem Description
Troubleshooting
9530336
Items have been left in the
transport or exit slot as a result
of a prior Dispense, Present or
Recycler Cash-In operation.
1. Check the sequence flow for AP
2. In spite of normal if abnormal
performance, need to analyze trace log
as being get the log.
9590500
Abnormal operation mode
1. Check RBU Dipswitch 5 status
2. In spite of normal if abnormal
performance, need to analyze trace log
as being get the log.
95D0014
It is occurred hardware error
during Transaction
ex) during the dispense, reject,
retract, cash in, cash in end
and reset command
1. check the occurred error path or unit.
2. In spite of normal if abnormal
performance, need to analyze trace log
as being ge the log.
95D0015
Failed to allocate memory
during xfs command
1. check the allocated memory from AP
and SP
2. In spite of normal if abnormal
performance, need to analyze trace log
as being get the log.
95D0048
It is occurred to timeout during
the xfs command
1. check input timeout value from AP.
95D0049
unsupport category
AP should not use this command
95D0050
It is unsupport command
during xfs command.
1. Unsupport command
95D0052
Invalid memory, in case of
input cash unit numver 0 and
mixnumber is individual when
send denominate command.
1. check the input data from AP
2. In spite of normal if abnormal
performance, need to analyze trace log
as being get the log.
95D0053
Not matched request count
and sum of the request count :
possibility is zero.
1. In spite of normal if abnormal
performance, need to analyze trace log
as being get the log.
95D0057
unsupport command data
Check AP parameter for XFS command
95D0058
command sequence error
Check AP transaction flow
95D0312
Failed to open shutter
1. check the shutter
2. check the positon for upper unit and
outputposion
95D1300
Invaild currency
Check useing currency
95D1302
cash unit error
check the casette
95D1307
There were too many items
inserted for cash in. The Cash-
In stacker is full.
1. Check the sequence flow for AP.
2. confirm the max accept count.
3. In spite of normal if abnormal
performance, need to analyze trace log
as being get the log.
95D1308
The position specified is not
supported.
1. Check the input data from AP
2. In spite of normal if abnormal
performance, need to analyze trace log
as being get the log.
95D1312
failed to open shutter
check the shutter
check the position for upper unit and
outputposition
95D1315
The cash unit number
specified is not valid.
1. Check the input data from AP
2. In spite of normal if abnormal
performance, need to analyze trace log
as being get the log.