![background image](http://html1.mh-extra.com/html/nautilus-hyosung/mx8800/mx8800_manual_3517484517.webp)
Chapter2. Bill Recycling Machine (BRM) Error Code Manual
© 2014
Nautilus Hyosung Inc.
All Rights Reserved.
2-513
Code
Problem Description
Troubleshooting
5QA2Q00
Status of remaining notes on
the return Path(GS034) before
the operation during Retract
CSM + TE.
1. Open the lower unit
2. Rotate the knob of the Mid Transport
Path
3. Remove notes and substance in the
Mid Transport Path(13)
4. Check whether the sensor is
contaminated or not if there are No
notes or substance
5QA2W00
Status of remaining notes on
the return Path(GS802) before
the operation during Retract
CSM + TE.
1. Open the upper unit
2. Open the customer service module
(CSM)
3. Open the BC(5)
4. Remove notes and substance in the
BC(5)
5. Check whether the sensor is
contaminated or not if there are No
notes or substance
5QAA100
Status of UTC removal before
the operation during Retract
CSM + TE.
1. Open the upper unit
2. Check removal of the cassette not
received(9)
5QAA200
Status of TE open before the
operation during Retract CSM
+ TE.
1. Open the upper Unit
2. Check open/close of TE(12)
5QAA300
Status of BMU inter lock
detachment before the
operation during Retract CSM
+ TE.
1. Check Load/Removal of the upper
unit
2. Replace a cherry switch when error
occures
5QAA400
Status of BMU removal before
the operation during Retract
CSM + TE.
1. Check Load/Removal of the upper
unit
5QAA500
Status of Safe door open
before the operation during
Retract CSM + TE.
1. Check the safe door open
5QAA600
Status of CSM open before the
operation during Retract CSM
+ TE.
1. Open the upper Unit
2. Check open/close of CSM
3. Check sensor GS011
5QAA700
Status of RJC removal before
the operation during Retract
CSM + TE.
1. Open the lower unit
2. Open the Mid Transport Path
3. Check the reject CST(21)
Load/Removal
5QAA800
Status of BMD inter lock
detachment before the
operation during Retract CSM
+ TE.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
5QAA900
Status of BMD removal before
the operation during Retract
CSM + TE.
1. Check the lower Unit load/removal
2. Check the lower unit status of inter
lock
3. Exchange the cherry switch or clean
the inter lock sensor(or exchange) if
occur same error
5QAAA00
Status of BC open before the
operation during Retract CSM
+ TE.
1. Open the upper unit
2. Check the lock lever in the BC