GENERAL DESCRIPTION

The G308 Operator Interface Terminal combines unique capabilities

normally expected from high-end units with a very affordable price. It is built
around a high performance core with integrated functionality. This core allows
the G308 to perform many of the normal features of the Paradigm range of
Operator Interfaces while improving and adding new features.

The G308 is able to communicate with many different types of hardware using

high-speed RS232/422/485 communications ports and Ethernet 10 Base T/100
Base-TX communications. In addition, the G308 features USB for fast downloads
of configuration files and access to trending and data logging. A CompactFlash
socket is provided so that Flash cards can be used to collect your trending and
data logging information as well as to store larger configuration files.

In addition to accessing and controlling of external resources, the G308

allows a user to easily view and enter information. Users can enter data through
the touchscreen or front panel 7-button keypad.

SAFETY SUMMARY

All safety related regulations, local codes and instructions that appear in the

manual or on equipment must be observed to ensure personal safety and to
prevent damage to either the instrument or equipment connected to it. If
equipment is used in a manner not specified by the manufacturer, the protection
provided by the equipment may be impaired.

Do not use the controller to directly command motors, valves, or other

actuators not equipped with safeguards. To do so can be potentially harmful to
persons or equipment in the event of a fault to the controller.

CONTENTS OF PACKAGE

- G308 Operator Interface.
- Panel gasket.
- Template for panel cutout.
- Hardware packet for mounting unit into panel.
- Terminal block for connecting power.

ORDERING INFORMATION

1

Contact your Red Lion distributor or visit our website for complete selection.

2

Use this part number to purchase Crimson on CD with a printed 

manual, USB cable, and RS-232 cable. Otherwise, download from
www.redlion.net.

3

Red Lion offers RJ modular jack adapters. Refer to the DR literature for

complete details.

4

Battery type is lithium coin type CR2025.

5

Industrial grade two million write cycles.

MODEL G308A - GRAPHIC LCD OPERATOR INTERFACE TERMINAL WITH 

VGA DISPLAY AND TOUCHSCREEN

Bulletin No.  G308A-E
Drawing No.  LP0613
Released  1/08

Tel +1 (717) 767-6511
Fax +1 (717) 764-0839
www.redlion.net

CompactFlash is a registered trademark of CompactFlash Association.

z

CONFIGURED USING CRIMSON SOFTWARE (VERSION 2.0 BUILD

187 OR LATER)

z

UP TO 5 RS-232/422/485 COMMUNICATIONS PORTS 

(2 RS-232 AND 1 RS-422/485 ON BOARD, 1 RS-232 AND 1
RS422/485 ON OPTIONAL COMMUNICATIONS CARD)

z

10 BASE T/100 BASE-TX ETHERNET PORT TO NETWORK UNITS

AND HOST WEB PAGES

z

USB PORT TO DOWNLOAD THE UNIT’S CONFIGURATION FROM

A PC OR FOR DATA TRANSFERS TO A PC

z

UNIT’S CONFIGURATION IS STORED IN NON-VOLATILE MEMORY

(8 MBYTE FLASH)

z

COMPACTFLASH

®

SOCKET TO INCREASE MEMORY CAPACITY

z

8.4-INCH TFT DISPLAY (256 COLOR, VGA 640X480 PIXELS)

z

7-BUTTON KEYPAD FOR ON-SCREEN MENUS

z

THREE FRONT PANEL LEDS

z

POWER UNIT FROM 24VDC ±20% SUPPLY

z

RESISTIVE ANALOG TOUCHSCREEN

CAUTION: Risk of Danger

Read complete instructions prior to

installationand operation of the unit.

CAUTION: 

Risk of electric shock.

MODEL NO.

DESCRIPTION

PART NUMBER

512 MB CompactFlash Card 

5

64 MB CompactFlash Card 

5

256 MB CompactFlash Card 

5

G3CF512M

G3CF064M
G3CF256M

G308A000

G3CN

G3RS

CANopen Optional Communication Card

RS232/485 Optional Communication Card

G3CN0000

G3RS0000

PSDR

G3PBDP

Mini Power Supply 1 A

Profibus DP Optional Communication Card

PSDR0100

G3PBDP00

SFCRM2

Crimson 2.0 

2

SFCRM200

CBL

RS-232 Programming Cable

CBLPROG0

G3CF

G308A

USB Cable

CBLUSB00

Communications Cables 

1

CBLxxxxx

G3FILM

Protective Films

Replacement Battery 

4

G3FILM08

BNL20000

DR

DIN Rail Mountable Adapter Products 

3

DRxxxxxx

Operator Interface with TFT display for 
indoor applications, textured finish with
embossed keys 

FOR USE IN HAZARDOUS LOCATIONS:

Class I, Division 2, Groups A, B, C, and D
Class II, Division 2, Groups F and G
Class III, Division 2

63YN

LABORATORY EQUIPMENT

The protective conductor terminal is bonded to conductive
parts of the equipment for safety purposes and must be
connected to an external protective earthing system.

WARNING - EXPLOSION HAZARD - SUBSTITUTION OF

COMPONENTS MAY IMPAIR SUITABILITY FOR CLASS I,

DIVISION 2/CLASS II, DIVISION 2/CLASS III, DIVISION 2

Summary of Contents for G308A

Page 1: ...e details 4 Battery type is lithium coin type CR2025 5 Industrial grade two million write cycles MODEL G308A GRAPHIC LCD OPERATOR INTERFACE TERMINAL WITH VGA DISPLAY AND TOUCHSCREEN Bulletin No G308A E Drawing No LP0613 Released 1 08 Tel 1 717 767 6511 Fax 1 717 764 0839 www redlion net CompactFlash is a registered trademark of CompactFlash Association z CONFIGURED USING CRIMSON SOFTWARE VERSION 2...

Page 2: ...omponent Recognition Program of Underwriters Laboratories Inc Type 4X Enclosure rating Face only UL50 UL Listed File E211967 UL61010 1 UL1604 CSA 22 2 No 61010 1 CSA 22 2 No 213 M1987 LISTED by Und Lab Inc to U S and Canadian safety standards IECEE CB Scheme Test Certificate US 9737C UL CB Scheme Test Report E179259 V01 S04 Issued by Underwriters Laboratories Inc IEC 61010 1 EN 61010 1 Safety requ...

Page 3: ... low voltage Safety extra low voltage circuits shall exhibit voltages safe to touch both under normal operating conditions and after a single fault such as a breakdown of a layer of basic insulation or after the failure of a single component has occurred CONFIGURING A G308 The G308 is configured using Crimson software Crimson is available as a free download from Red Lion s website or it can be pur...

Page 4: ...Rx 3 Tx N C 4 DTR 3 COM 5 GND N C 6 DSR 1 CTS 7 RTS 6 RTS 8 CTS N C 9 RI 1 CBLPROG0 can also be used to communicate with either a PC or an ICM5 2 DB9 adapter not included 1 foot long 3 DB9 adapter not included 10 feet long ETHERNET COMMUNICATIONS Ethernet communications can be established at either 10 BASE T or 100 BASE TX The G308 unit s RJ45 jack is wired as a NIC Network Interface Card For exam...

Page 5: ...ler CBLRLC05 TxA 8 TxA 8 TxB 7 TxB 7 COM 6 COM 6 TxEN 5 TxEN 5 RxA TxA 3 2 2 3 RxA TxA 3 2 2 3 RxB 4 1 RxB 4 1 TxB 1 4 TxB 1 4 Name Modular Controller Name G3 Connections DH485 COMMUNICATIONS The G308 s RS422 485 COMMS port can also be used for Allen Bradley DH485 communications WARNING DO NOT use a standard DH485 cable to connect this port to Allen Bradley equipment A cable and wiring diagram are...

Page 6: ...lock the drive unless they need to write data Windows 98 may lock the drive any time it is mounted thereby interfering with logging Refer to Mounting the CompactFlash in the Crimson 2 User Manual TOUCHSCREEN This operator interface utilizes a resistive analog touchscreen for user input The unit will only produce an audible tone beep when a touch on an active touchscreen cell is sensed The touchscr...

Page 7: ...our local waste regulations Also the battery must not be disposed of in fire or in a manner whereby it may be damaged and its contents come into contact with human skin The battery used by the G308 is a lithium type CR2025 CAUTION RISK OF ELECTRIC SHOCK The inverter board attached to the mounting plate supplies the high voltage to operate the backlight Touching the inverter board may result in inj...

Page 8: ... II cards Use cards with a minimum of 4 Mbytes and a maximum of 2 Gbytes with the G308 s CompactFlash socket Cards are available at most computer and office supply retailers CompactFlash can be used for configuration transfers larger configurations data logging and trending Information stored on a CompactFlash card by a G308 can be read by a card reader attached to a PC This information is stored ...

Reviews: