Time-Domain Link (TiDL) Firmware Upgrade
This only affects time stamps recorded and stored by the relay prior to the firm-
ware upgrade. All time stamps in Demand Metering and Breaker Monitoring fol-
lowing the firmware upgrade will be UTC time with the local time offset setting
(UTCOFF) and daylight-saving time applied.
No other reports (Event History, Event Summary, SER, etc.) are affected.
Time-Domain Link (TiDL) Firmware Upgrade
The relay firmware will be upgraded through the standard upgrade process shown
above. The TiDL interface board has its own firmware upgrade process, and the
firmware for the TiDL interface board is stored on an SD card. This procedure
will upgrade the TiDL interface board as well as the connected Axion modules.
The firmware for the TiDL interface board can be determined by issuing the
VERSION
command in the relay (see
To upgrade the firmware, perform the following steps.
Remove From Service
Step 1. Remove the unit from service.
Step 2. Turn the unit off.
Step 3. Remove the front panel.
Upgrade
Step 1. Copy the ECB and SEL-2245 firmware .zds files from the upgrade
CD to an SD card.
Step 2. Install the SD card in the SD card slot indicated in
.
Step 3. Turn the unit on.
Step 4. Wait for the upgrade to complete. (See the accompanying note.)
=>>VER <ENTER>
FID=SEL-451-5-R317-V0-Z022012-D20160728
CID=FFE8
Part Number: 0451543RRC4X4H60X0XXX
Serial Number: 0000000000
SELboot:
BFID= SLBT-4XX-R209-V0-Z001002-D20150130
Checksum: 0000
ECB FID= R100
Mainboard:
Code FLASH Size: 12 MB
Data FLASH Size: 52 MB
RAM Size: 64 MB
EEPROM Size: 128 kB
Front Panel: not installed
Analog Inputs (provided by remote Axion Nodes):
W: Currents: 5 Amp
X: Currents: 5 Amp
Y: Voltage: 67 Volts
Z: Voltage: 67 Volts
Interface Boards:
Board 1: not installed
Remote I/O: 72 inputs 48 outputs
E4 Configuration: 4
Extended Relay Features:
IEC 61850
Figure B.6
EtherCAT Cal Board (ECB) FID
Summary of Contents for SEL-421-4
Page 6: ...This page intentionally left blank ...
Page 14: ...This page intentionally left blank ...
Page 30: ...This page intentionally left blank ...
Page 104: ...This page intentionally left blank ...
Page 128: ...This page intentionally left blank ...
Page 536: ...This page intentionally left blank ...
Page 584: ...This page intentionally left blank ...
Page 616: ...This page intentionally left blank ...
Page 696: ...This page intentionally left blank ...
Page 750: ...This page intentionally left blank ...
Page 755: ...Instruction Manual PM400 01 NB SEL 400 Series Relays Instruction Manual 20171006 ...
Page 776: ...This page intentionally left blank ...
Page 932: ...This page intentionally left blank ...
Page 976: ...This page intentionally left blank ...
Page 1024: ...This page intentionally left blank ...
Page 1038: ...This page intentionally left blank ...
Page 1064: ...This page intentionally left blank ...
Page 1128: ...This page intentionally left blank ...
Page 1206: ...This page intentionally left blank ...
Page 1316: ...This page intentionally left blank ...
Page 1350: ...This page intentionally left blank ...
Page 1464: ...This page intentionally left blank ...
Page 1468: ...This page intentionally left blank ...
Page 1492: ...This page intentionally left blank ...
Page 1518: ...This page intentionally left blank ...