![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799255.webp)
8
-5
8 Safety Function
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
8
-2 Operati
on Exam
ple
8
8
-2
Operation Example
This section provides timing charts showing the operation timings to enter a safety status and the timing
of return from a safety status.
*1
STO status is entered when either safety input 1 or 2 turns
“
OFF.
”
*2
The dynamic brake operates according to the setting of the Fault reaction option code (605E hex).
*3
t1 is the set value of the Brake Timing During Operation (3438 hex), or the time needed for the motor speed to
drop to or below the Brake Threshold Speed During Operation (3439 hex), whichever occurs first.
Operation Timings to a Safety Status
READY
t1
*3
Response time = max 5ms
ON
OFF
Response time = max 6ms
0.5 to 5ms
Servo ON/OFF
Servo ON
STO status
DB released
DB engaged
Value set in 3438 hex
Value set in 3438 hex
When object 3438 hex
set value comes earlier
When object 3439 hex
set value comes earlier
Motor power is supplied.
Dynamic
brake relay
*2
Servo ready completed
output (READY)
Error output
(/ALM)
Brake interlock
output (BKIR)
Brake interlock
output (BKIR)
Servo OFF
EDM output
Error
Brake engaged
Brake released
Brake engaged
Safety input 1
Safety input 2
*1
No power supply
Power supply
Normal status
Brake released
Normal
Motor speed
Value set in 3439 hex
Motor speed
Value set in 3439 hex