![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799509.webp)
A-109
Appendicies
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
A
-3 Sysm
ac Err
o
r Sta
tus
Cod
es
App
A-3
-2 Error D
escr
iption
Event name
Main Circuit Power Supply Undervoltage (AC Cutoff
Detected)
Event code
04AB0000 hex
Meaning
If the Undervoltage Error Selection (3508 hex) is set to 1, a momentary power interruption occurred between L1 and L3
for longer than the value specified for the Momentary Hold Time. The voltage between the positive and negative
terminals in the main power supply converter dropped below the specified value while the Servo was ON.
Source
EtherCAT Master Function Module
Source details
Slave
Detection
timing
While power is
supplied to motor
Error attributes
Level
Minor fault
Recovery
Error reset (after
resetting slave
errors)
Log category
System
Effects
User program
Continues.
Operation
Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN
EtherNet/IP NET ERR
EtherNet/IP LINK/ACT
---
---
---
System-defined
variables
Variable
Data type
Name
None
---
---
Cause and
correction
Assumed cause
Remedy
Prevention
Insufficient power supply capacity
Increase the power supply capacity.
None
The electromagnetic contactor in the
main circuit power supply was
tripped.
Eliminate the cause of the failure of
the electromagnetic contactor on the
main circuit power supply, and then
turn ON the power again.
Check the wiring of the main circuit
power supply.
A momentary power interruption
occurred.
Review the power supply conditions
and prevent momentary power
interruption. Alternatively, increase
the Momentary Hold Time (3509 hex)
setting.
Make sure that the power supply
conditions prevent momentary power
interruption.
A Servo Drive with 3-phase input
specifications was operated with a
single-phase power supply.
Make sure that the phases of the
power supply are set correctly before
you connect them.
Make sure that the phases of the
power supply are set correctly before
you connect them.
The Servo Drive failed.
Replace the Servo Drive.
None
Attached
information
None
Precautions/
Remarks
“
13
”
is displayed on the Servo Drive front panel and F113 is given as the AlarmCode (4001 hex)