Set the Damping Filter Selection (3213 hex).
Damping filters 1 to 4 can be switched according to the conditions of the machine vibration.
*1
The set value 1 and 2 are reserved for system use. Users are not allowed to set 1 and 2 for this object.
*2
The table below shows the damping filter you can switch to based on the command direction.
Set value
Description
0
Up to two filters, Damping Filter 1 and Damping Filter 2, can be used simultaneously.
1
Reserved
*1
2
Reserved
*1
3
The damping filters are switched in the direction of the position command.
*2
Direction of
position
command
Damping
filter 1
Damping
filter 2
Damping
filter 3
Damping
filter 4
Positive
Enabled
Disabled
Enabled
Disabled
Negative
Disabled
Enabled
Disabled
Enabled