![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799521.webp)
A-121
Appendicies
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
A
-3 Sysm
ac Err
o
r Sta
tus
Cod
es
App
A-3
-2 Error D
escr
iption
Event name
Object Corrupted
Event code
14AB0000 hex
Meaning
The checksum data in non-volatile memory is corrupted.
Source
EtherCAT Master Function Module
Source details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the
slave
Error attributes
Level
Minor fault
Recovery
Error reset (after
cycling slave
power)
Log category
System
Effects
User program
Continues.
Operation
Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN
EtherNet/IP NET ERR
EtherNet/IP LINK/ACT
---
---
---
System-defined
variables
Variable
Data type
Name
None
---
---
Cause and
correction
Assumed cause
Remedy
Prevention
Non-volatile memory failure
Replace the Servo Drive.
None
Attached
information
None
Precautions/
Remarks
“
37
”
is displayed on the Servo Drive front panel and F037 is given as the AlarmCode (4001 hex).
Event name
Object Corrupted
Event code
14AC0000 hex
Meaning
The checksum data in non-volatile memory is corrupted.
Source
EtherCAT Master Function Module
Source details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the
slave
Error attributes
Level
Minor fault
Recovery
Error reset (after
cycling slave
power)
Log category
System
Effects
User program
Continues.
Operation
Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN
EtherNet/IP NET ERR
EtherNet/IP LINK/ACT
---
---
---
System-defined
variables
Variable
Data type
Name
None
---
---
Cause and
correction
Assumed cause
Remedy
Prevention
Non-volatile memory failure
Replace the Servo Drive.
None
Attached
information
None
Precautions/
Remarks
“
37
”