![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799399.webp)
12-29
12 Troubleshooting and Maintenance
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
12-5 P
eriodi
c Maintenan
ce
12
•
The lifetimes for the different drive parts are given below.
Aluminum electrolytic capacitors: 28,000 hours
(at an ambient drive operating temperature of 55
C, constant output at rated force, constant output at
rated speed, and installation as described in this manual)
Axial-flow fan: 10,000 to 30,000 hours (The limit depends on the operating conditions.)
Inrush current prevention relay: Approx. 20,000 operations (The limit depends on the operation
conditions.)
•
When using the Servo Drive in continuous operation, use fans or air conditioners to maintain the
ambient temperature below 40
C.
•
We recommend that the ambient temperature and the power supply ON time be reduced as much as
possible to lengthen the service life of the Servo Drive.
•
The limit of aluminum electrolytic capacitors is greatly affected by the ambient operating temperature.
Generally, an increase of 10
C in the operating ambient temperature will reduce capacitor service life
by 50%.
For example, when the ambient operating temperature is 25
C, the life expectancy will be as follows:
•
The aluminum electrolytic capacitors deteriorate even when the Servo Drive is stored with no power
supplied. If the Servo Drive is not used for a long time, we recommend periodic inspection and a part
replacement period of 5 years.
•
If the motor or Servo Drive is not to be used for a long time, or if they are to be used under conditions
worse than those described above, a periodic inspection period of 5 years is recommended.
•
Upon request, OMRON will inspect the Servo Drive and motor and determine if part replacement is
required.
Servo Drive Life Expectancy
Life expectancy at 25°C = Life expectancy at 55°C × 2
55 - 25
10
= 224,000 hours