![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799534.webp)
Appendicies
A-134
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Event name
Interface Input Function Number Error 1
Event code
38470000 hex
Meaning
There is an undefined number specification in the input signal (IN1, IN2, IN3, and IN4) function allocations. Or, a logic
setting error was detected.
Source
EtherCAT Master Function Module
Source details
Slave
Detection
timing
When
establishing
communications
after turning ON
power to the
slave or when
transferring
EtherCAT
Configuration
Setup
Error attributes
Level
Minor fault
Recovery
Error reset (after
cycling slave
power)
Log category
System
Effects
User program
Continues.
Operation
Power drive circuit is OFF for relevant slave.
Indicators
EtherNet/IP NET RUN
EtherNet/IP NET ERR
EtherNet/IP LINK/ACT
---
---
---
System-defined
variables
Variable
Data type
Name
None
---
---
Cause and
correction
Assumed cause
Remedy
Prevention
There is an undefined number
specification in the input signal (IN1,
IN2, IN3, and IN4) function
allocations.
Allocate the functions to the
connector pins using only the
numbers that are defined.
Allocate the functions to the
connector pins using only the
numbers that are defined.
Different logic is set for the same
function in the function assignments
of the input signals (IN1, IN2, IN3,
and IN4).
Correct the settings so that the same
logic is used for the same function.
Use the same logic for the same
function.
Attached
information
None
Precautions/
Remarks
“
33
”