A-99
Appendicies
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
A
-3 Sysm
ac Err
o
r Sta
tus
Cod
es
App
A-3
-1 Error T
ab
le
38490000 hex
Interface
Output
Function
Number Error
1
There is an
undefined number
specification in the
output signal
(OUTM1) function
allocation.
•
There is an undefined number
specification in the output
signal (OUTM1) function
allocation.
384A0000 hex
Interface
Output
Function
Number Error
2
There is an
undefined number
specification in the
output signal
(OUTM2) function
allocation.
•
There is an undefined number
specification in the output
signal (OUTM2) function
allocation.
384B0000 hex
External
Latch Input
Allocation
Error
There is an error in
the latch input
function allocation.
•
The latch input was allocated to
an input signal other than IN5,
IN6, or IN7.
•
A latch input is assigned to an
NC signal.
•
The same latch input is not
assigned to the same pin in all
Control Modes.
384C0000 hex
Overrun Limit
Error
The motor
exceeded the
allowable operating
range set in the
Overrun Limit
Setting (3514 hex)
with respect to the
position command
input range.
•
The gain or mass ratio is not
suitable.
•
The set value of the Overrun
Limit Setting (3514 hex) is too
small.
384F0000 hex
Object
Setting Error
1
The electronic gear
ratio exceeded the
allowable range.
•
The electronic gear ratio
exceeded the allowable range.
38500000 hex
Object
Setting Error
2
External encoder
ratio exceeded the
allowable range.
•
External encoder ratio
exceeded the allowable range.
38510000 hex
External
Encoder
Connection
Error
The set value of the
External Feedback
Pulse Type
Selection (3323
hex) differs from the
external encoder
type that is
connected for serial
communications.
•
The set value of the External
Feedback Pulse Type Selection
(3323 hex) differs from the
external encoder type that is
connected for serial
communications.
38520000 hex
Function
Setting Error
The function that
was set does not
support the
communications
period.
•
The electronic gear object ratio
was not 1:1 when the
communications period was set
to 250 or 500
s.
•
Modes of operation (6060 hex)
was set to pp or hm when the
communications period was set
to 250 or 500
s.
•
More than 20 bytes were
mapped for RxPDO when the
communications period was set
to 250
s.
•
No bytes (i.e., no objects) were
mapped for RxPDO.
•
More than 10 objects were
mapped for RxPDO.
•
More than 11 objects were
mapped for TxPDO.
Event code
Event name
Meaning
Assumed cause
Level
Reference
Maj
Prt
Min
Obs
Info