9 Servo Parameter Objects
9-2
8
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
•
Set the function and logic for general-purpose input 6 (IN6).
Refer to the Details of Control Inputs in
on page 3-9, as well as
•
Set the function and logic for general-purpose input 7 (IN7).
Refer to the Details of Control Inputs in
on page 3-9, as well as
•
Set the function and logic for general-purpose input 8 (IN8).
Refer to the Details of Control Inputs in
on page 3-9, as well as
•
Set the function assignment for general-purpose output 1 (OUTM1).
Refer to the Details of Control Inputs in
on page 3-12, as well as
•
Set the function assignment for general-purpose output 2 (OUTM2).
Refer to the Details of Control Inputs in
on page 3-12, as well as
3405 hex
Input Signal Selection 6
Setting range
0 to 00FF
FFFF hex
Unit
Default
setting
0021 2121 hex
Data
attribute
C
Size
4 bytes (INT32)
Access
RW
PDO map
Not possible.
3406 hex
Input Signal Selection 7
Setting range
0 to 00FF
FFFF hex
Unit
Default
setting
0020 2020 hex
Data
attribute
C
Size
4 bytes (INT32)
Access
RW
PDO map
Not possible.
3407 hex
Input Signal Selection 8
Setting range
0 to 00FF
FFFF hex
Unit
Default
setting
002E 2E2E hex
Data
attribute
C
Size
4 bytes (INT32)
Access
RW
PDO map
Not possible.
3410 hex
Output Signal Selection 1
Setting range
0 to 00FF
FFFF hex
Unit
Default
setting
0003 0303 hex
Data
attribute
C
Size
4 bytes (INT32)
Access
RW
PDO map
Not possible.
3411 hex
Output Signal Selection 2
Setting range
0 to 00FF
FFFF hex
Unit
Default
setting
0002 0202 hex
Data
attribute
C
Size
4 bytes (INT32)
Access
RW
PDO map
Not possible.
All
All
All
All
All