![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799267.webp)
9-9
9 Servo Parameter Objects
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
9-2 Gain
Setti
ngs
9
•
Set the time constant for the low pass filter (LPF) after speed detection to one of 6 levels (0 to 5).
•
Increasing the set value increases the time constant and decreases the noise generated by the
motor. Responsiveness, however, also decreases.
•
Normally, use the default set value.
*1
The default setting is 126 for a Drive with 200 V and 1 kW or greater, or with 400 V.
•
Set the time constant for the first-order lag filter inserted into the force command.
•
This object may be effective in suppressing vibration due to torsion resonance.
*1
The default setting is 380 for a Drive with 200 V and 1 kW or greater, or with 400 V.
•
Set the responsiveness of the position control system for the second position loop.
*1
The default setting is 180 for a Drive with 200 V and 1 kW or greater, or with 400 V.
•
Set the responsiveness of the second speed loop.
•
Set the second speed loop integral time constant.
•
Set the second speed feedback filter.
3103 hex
Speed Feedback Filter Time Constant 1
Setting range
0 to 5
Unit
Default setting
0
Data attribute
B
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible.
3104 hex
Force Command Filter Time Constant 1
Setting range
0 to 2500
Unit
0.01 ms
Default setting
84
*1
Data attribute
B
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible.
3105 hex
Position Loop Gain 2
Setting range
0 to 30000
Unit
0.1/s
Default setting
570
*1
Data attribute
B
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible.
3106 hex
Speed Loop Gain 2
Setting range
1 to 32767
Unit
0.1 Hz
Default setting
270
*1
Data attribute
B
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible.
3107 hex
Speed Loop Integral Time Constant 2
Setting range
1 to 10000
Unit
0.1 ms
Default setting
10000
Data attribute
B
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible.
310
8
hex
Speed Feedback Filter Time Constant 2
Setting range
0 to 5
Unit
Default setting
0
Data attribute
B
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible.
All
All
csp
pp
hm
All
All
All