![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799207.webp)
6-17
6 Basic Control Functions
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
6-6 Con
n
ecting
with OMR
O
N C
o
n
tr
o
ller
s
6
CJ1W-NC2
8
1/NC4
8
1/NC
88
1/NCF
8
1/NC4
8
2/NC
88
2/NCF
8
2 Position Control
Units
*1
The CJ1W-NC
8
uses the latch signals as follows:
External Latch Signal 1: Origin Input
External Latch Signal 2: Interrupt Input
External Latch Signal 3: Not used.
Index
Sub-
index
Name
Default setting
Description
3013 hex
00 hex
Force Limit 1
5000
Default setting is 500.0%
3401 hex
00 hex
Input Signal Selection 2
00818181 hex
Positive Drive Prohibition Input (NC)
3402 hex
00 hex
Input Signal Selection 3
00828282 hex
Negative Drive Prohibition Input (NC)
3403 hex
00 hex
Input Signal Selection 4
00222222 hex
Home Proximity Input (NO)
3404 hex
00 hex
Input Signal Selection 5
002B2B2B hex
External Latch Signal 3 (NO)
*1
3405 hex
00 hex
Input Signal Selection 6
00212121 hex
External Latch Signal 2 (NO)
*1
3406 hex
00 hex
Input Signal Selection 7
00202020 hex
External Latch Signal 1 (NO)
*1
3504 hex
00 hex
Drive Prohibition Input
Selection
1
The drive prohibition input is disabled in the
servo and processed in the controller.
3508 hex
00 hex
Undervoltage Error
Selection
1
Stopping for undervoltage errors.
3521 hex
00 hex
Force Limit Selection
6
Both positive and negative directions have two
limits which are switched using PCL and NCL.
3522 hex
00 hex
Force Limit 2
5000
Default setting is 500.0%
3801 hex
00 hex
Software Position Limit
Function
3
Disable the software limits in both directions.
3758 hex
00 hex
Touch Probe Trigger
Selection
0100 hex
Touch probe1 = External Latch Signal 1
Touch probe2 = External Latch Signal 2
3759 hex
00 hex
Warning Hold Selection
0000 hex
Automatically cleared when the cause is
removed.
607C hex
00 hex
Home offset
0
An offset value of 0 is used by the Servo Drive.
6091 hex
01 hex
Motor revolutions
1
Gear ratio used by the Servo Drive is 1:1, and
user units are handled by the controller.
02 hex
Shaft revolutions
1
60E0 hex
00 hex
Positive torque limit value
5000
Default setting is 500.0%
60E1 hex
00 hex
Negative torque limit value
5000
Default setting is 500.0%