background image

Panasonic

Summary of Contents for EYFR03

Page 1: ...Panasonic...

Page 2: ...istory Events Qualifier Settings Protocols Network Settings Inputs Outputs Update Firmware Check Firmware Assembly Manager Connecting A PC Data Collection Download Data To USB Configuration To USB Upl...

Page 3: ...EYFR03 Model Comparison Page 3...

Page 4: ...n Protocol ToolsNet EYFR03A B Remote I O 5 Pin Connector For Future Use I O Module Used in EYFR03A B Discrete I O 24 Pin Connector Used to connect directly to the assembly line or a PLC 8 Inputs 12 Ou...

Page 5: ...Lock Unit Radio Status Network Status Reset Batch History Status Current configurations Menu Access to setting up the Qualifier Password 1011 Parameter Name Tool Name Batch Count EYFR03 Run Screen Gro...

Page 6: ...lifier Settings Events View non tightening events such as programming and tool changes power ups etc Lock Exit Exit and Lock Out Menu Returns to Run Screen Exit Exit Menu Returns to Run Screen EYFR03...

Page 7: ...ool menu and the box will turn green 3 To learn additional tools return to the Learn step above 4 Exit Returns to the Main Menu Tools Learn Learn Open Main menu Tools Learn Tool Menu Page 7 In the cas...

Page 8: ...n step above 4 Exit Returns to the Main Menu 1 Editable Fields a Tool Name b Serial Number c Last Calibration d Next Calibration e Last PM f Cycles before PM 2 Not Editable Fields a Radio Info b Cycle...

Page 9: ...omplete once the group all fasteners are completed for each tool Free Run Mode Each tool can run independently and report an independent batch complete for each tool Uses When a group of tools are req...

Page 10: ...n Arrow over to the Parameter to run Press Select EYFR03 Create And Run A Parameter The Run Screen should be showing and is now ready to run a Parameter When a tool is learned into the Qualifier a par...

Page 11: ...Batch Count c Lock On Batch d Time Between Cycles Seconds e Time Between Batches Seconds 2 Not Editable Fields a Tool Name Paste Paste copied parameter into highlighted cell Paste can only be used on...

Page 12: ...tools attached to the Group Press Exit and the Qualifier returns to the Group edit screen EYFR03 Create And Run A Group Choose the different tools to be attached to the Group Arrow over to the Group t...

Page 13: ...oup 2 Parameter d Free Run Mode 1 No 2 Yes Paste Paste copied group into highlighted cell Exit Enter Returns to the Main Menu Group Select Edit Copy Parameters Goes to the parameter selection Delete D...

Page 14: ...attached to the Job Press Exit and the Qualifier returns to the Job edit screen EYFR03 Create And Run A Job Choose the different Parameters Groups to be attached to the Job Arrow over to the Job to r...

Page 15: ...ber of Steps Paste Paste copied group into highlighted cell Exit Enter Returns to the Main Menu Job Select Edit Copy Steps Goes to the parameter and or group selection Delete Deletes all information i...

Page 16: ...eturns to the Run Screen History View Main menu Events The History screen shows some information about the tightenings stored in unit memory More information about the tightenings is not shown but is...

Page 17: ...1 Enter Events Enter Next Steps to the next page of events Exit Events Returns to the Main Menu Events View Main menu Events Events Screen The Events screen shows the log of non tightening events that...

Page 18: ...lifier Settings f Network Settings g Tightenings h Events Reset All Resets All The Changes Cancel Cancels changes and returns to the qualifier settings Qualifier Settings View Edit 1 Editable Fields a...

Page 19: ...ct parameters groups jobs from a remote system PC ToolsNet Configure ToolsNet settings Use data collection purposes only EtherNet IP Configure general network settings Use select parameters groups job...

Page 20: ...VIN Outputs 12 The outputs can be configured to meet the needs of the customer Active Parameter Group or Job Tool Cycle Accept Tool Cycle Reject Tool Batch Complete Qualifier Suspended Remote I O 5 Pi...

Page 21: ...er Turn Qualifier On Insert USB into Qualifier Wait for Qualifier to detect USB Drive The Qualifier will automatically update then reboot itself Select Exit Select Upload USB File to Device Enter Sele...

Page 22: ...Run Screen Click Status Firmware Version is Listed at the Top EYFR03 Checking Firmware Version Page 22...

Page 23: ...ps Jobs View Qualifier Events Connect Via Ethernet Cable Directly Network Standard or Crossover Ethernet Cable Learning a tool has to be done at the Qualifier through the keypad screen EYFR03 Assembly...

Page 24: ...Follow the prompts 1 Click Next to continue install 2 Select Destination Location Click Next 3 Select Start Menu Folder Click Next 4 Select Additional Tasks Desktop Icon Click Next 5 Ready to Install...

Page 25: ...1 Configure General Menu with the following 1 IP Address 192 168 1 68 2 Subnet 255 255 255 0 3 Gateway 192 168 1 1 4 DHCP No 2 Cycle power of the Qualifier after changing the IP address 3 Configure t...

Page 26: ...Connect 2 Choose what you would like to read from the Qualifier and click Read 3 If the PC connects correctly to the Qualifier this screen will appear 4 Final screen after connection has been establis...

Page 27: ...0 0 0 0 0 0 0 1 20 6 12 17 2014 11 39 45 1 Parameter 1 12 6 2014 13 15 TRUE 35 0 1 1 0 0 0 0 0 0 0 0 0 0 1 21 6 12 17 2014 11 39 45 2 Parameter 2 12 6 2014 13 15 FALSE 0 0 1 2 0 0 0 0 0 0 0 0 0 0 2 2...

Page 28: ...B into Qualifier Wait for Qualifier to detect USB Drive The Qualifier will automatically download the file Press Cancel Button Select Download Device Data To USB Enter Select Items To Upload Results Y...

Page 29: ...USB into Qualifier Wait for Qualifier to detect USB Drive The Qualifier will automatically download the file Press Cancel Button Select Download Device Data To USB Enter Select Items To Upload Configu...

Page 30: ...folder Turn Qualifier On Insert USB into Qualifier Wait for Qualifier to detect USB Drive The Qualifier will automatically upload the file Press Cancel Button Select Upload USB File To Device Enter S...

Page 31: ...dress Click Connect Sync with Device Select what to sync click Read Upload tightenings to the PC EYFR03 Assembly Manager Software Create CSV Data File Top Menu click the Upload tightening results View...

Reviews: