![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799307.webp)
9-49
9 Servo Parameter Objects
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
9-7 Specia
l Ob
jects
9
•
Set the warning detection mask setting.
•
If you set the corresponding bit to 1, the corresponding warning detection is disabled.
Refer to the
Explanation of Settings
363
8
hex
Warning Mask Setting
Setting range
32768 to
32767
Unit
Default
setting
4
Data
attribute
C
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible.
Bit
Warning
number
Warning name
Warning condition
0 to 1
-
Reserved (Do not use.)
2
A7
Life Expectancy Warning
The life expectancy of the capacitor or the fan is
shorter than the specified value.
3
-
Reserved (Do not use.)
4
-
Reserved (Do not use.)
5
A1
Excessive Regeneration Warning
The regeneration load ratio is 85% or more of the
level.
6
A3
Fan Warning
The fan stops for 1 second.
7
A0
Overload Warning
The load ratio is 85% or more of the protection level.
8
A8
External Encoder Error Warning
The external encoder detects a warning.
9
A6
Vibration Detection Warning
Vibration is detected.
10
A9
External Encoder
Communications Warning
The external encoder has more communications
errors in series than the specified value.
All