![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799434.webp)
Appendicies
A-34
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
•
This is the mapping for an application that switches between Cyclic synchronous position mode (csp)
and Cyclic synchronous velocity mode (csv).
•
Touch probe and force limit are available.
1703 hex
260th receive PDO Mapping
Sub-index 00 hex
Number of objects in this PDO
Range
Unit
Default
07 hex
Attribute
Size
1 byte (U8)
Access
RO
PDO map
Not possible
Sub-index 01 hex
PDO entry 1 (1st Output Object to be mapped)
Range
Unit
Default
6040 0010 hex
Attribute
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 02 hex
PDO entry 2 (2nd Output Object to be mapped)
Range
Unit
Default
607A 0020 hex
Attribute
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 03 hex
PDO entry 3 (3rd Output Object to be mapped)
Range
Unit
Default
60FF 0020 hex
Attribute
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 04 hex
PDO entry 4 (4th Output Object to be mapped)
Range
Unit
Default
6060 0008 hex
Attribute
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 05 hex
PDO entry 5 (5th Output Object to be mapped)
Range
Unit
Default
60B8 0010 hex
Attribute
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 06 hex
PDO entry 6 (6th Output Object to be mapped)
Range
Unit
Default
60E0 0010 hex
Attribute
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
Sub-index 07 hex
PDO entry 7 (7th Output Object to be mapped)
Range
Unit
Default
60E1 0010 hex
Attribute
Size
4 bytes (U32)
Access
RO
PDO map
Not possible
All