![background image](http://html1.mh-extra.com/html/omron/r88d-kn-series/r88d-kn-series_user-manual_742799322.webp)
9 Servo Parameter Objects
9-64
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
•
Select one of the eight motor overload characteristic curves.
For details on the motor overload curves, refer to
3-2 Overload Characteristics (Electronic Thermal
Precautions for Correct Use
Precautions for Correct Use
•
The overload protection function is not designed to provide protection against errors caused
by heat generated by the motor.
•
Therefore, if you set the Motor Overload Curve Selection (3929 hex) value too high, the Motor
Coil Unit may burn. Check in the actual operating environment to be sure that no problem
occurs due to heat generated by the motor or other causes before using the Servo Drive.
3929 hex
Motor Overload Curve Selection
Setting range
0 to 7
Unit
–
Default setting
0
Data attribute
R
Size
2 bytes (INT16)
Access
RW
PDO map
Not possible.
All