11 Adjustment Functions
11-4
G5 Series AC Servo Drives With Built-in EtherCAT Communications, Linear Motor Type
Analog Monitor Output Setting (3421 Hex)
Select the direction for analog monitor output voltage.
The output voltage range and the data output direction when the Analog Monitor 1 Selection (3416 hex)
is set to 0 (motor speed) and the Analog Monitor 1 Scale Setting (3417 hex) is set to 0 are as shown
below.
The following explanation of settings also applies when the Analog Monitor 2 Selection (3418 hex) and
the Analog Monitor 2 Scale Setting (3419 hex) are set to 0.
Set value
Output range
Data output
0
10 to 10 V
1
0 to 10 V
2
0 to 10 V
(5 V as the center)
10 V
−
10 V
0 V
−
5000
5000 [mm/s]
Feedback
Motor Speed
Output voltage [V]
10 V
−
10 V
0 V
−
5000
5000 [mm/s]
Output voltage [V]
Feedback
Motor Speed
10 V
5 V
−
10 V
0 V
0
−
2500
2500 [mm/s]
Output voltage [V]
Feedback
Motor Speed