Introduction 

The JED T470 unit is a wall-mounted controller which communicates 
with a projector or flat panel via RS232 or IR. 

The T470 has an RS232 interface wired to a 5-way Phoenix connector 
and a CAT5. Tx and Rx lines only are provided, no handshake lines 
are used. 

If the unit is ordered with the –R2 option (two relay 

outputs), the RS232 connection can only be made via the CAT5 
cable. 

It also has a pin called “Res” which can be used as a PIR (Passive 
Infra-Red) input, an IR output or a voltage output to drive an external 
solid state (directly) or a mechanical relay (via an external FET 
device).  

Safety Instructions 

 

Caution: There are no operator serviceable parts inside the controller. 

 

Warning: Disconnect the power and unplug the power supply from the wall before installation. 

Power supply 

Both connectors also have a ground and a 12 volt input for power supply purposes. This can be unregulated 9 to 15 
volts DC, although JED normally supplies the T470 with a small regulated plug pack when sold into the Australian or 
New Zealand market. Current consumption is approximately 50mA. 

(Connections and wiring to the T470 are covered in the later part of this manual, page 6) 

Setting up the T470 

To set up the T470 it is necessary to connect the T470 RS232 port to a PC, either directly to a hardware RS-232 serial 
port or to a USB -> RS232 connection to the PC. 

While more details of wiring the T470 follow, basically the following 3-wire connections are needed. If the T470 does 
NOT have the relay option installed, this can be to the Phoenix screw terminals or via a short CAT5 cable. 
 

Function 

Phoenix screw 
 terminals  

CAT5 cable 
T-568A 

Connection to back of  female 
DB9 to PC or USB-DB9  

Ground 

Gnd 

Solid-Blue and Solid-Brown 

Pin 5 

RS232 from T470 to PC 

Tx 

Brown/White 

Pin 2 

RS232 to T470 from PC 

Rx 

Blue/White 

Pin 3 

Unused 

Res 

 

 

+12 volt input 

12v 

 

 

 
Connect a 12-volt power supply to the T470. Use a multimeter to verify polarity … the white stripe on the power 
adaptor cable sometimes indicates –ve, sove. A hint: strip 5mm of plastic from the wire and fold back once 
over the plastic. Open the screw fully, then slide wire AND plastic into the Phoenix screw terminal before tightening the 
screw on both. This makes for a stronger termination. It will start up with the red LED above the OFF key lit. 

Start the JED T470 Configuration Utility. This can be downloaded from: 

http://www.jedmicro.com.au/T470.html

  

A PDF user’s manual for the Configuration Utility is on-line, accessed via the “Help” button. 

Содержание T470

Страница 1: ...New Zealand market Current consumption is approximately 50mA Connections and wiring to the T470 are covered in the later part of this manual page 6 Setting up the T470 To set up the T470 it is necess...

Страница 2: ...red between the RES pin and Ground It is internally pulled up by a 4k7 resistor in this mode In IR Out mode IR pulses are transmitted from the RES pin on the back of the T470 and assume a positive cur...

Страница 3: ...t to a phantom demo training mode Clicking on Factory Reset will select a default phantom display device Code 0000h which is quite useful for demo and testing purposes It sets valid English language m...

Страница 4: ...tton of type which needs a 2 second contact closure on the first line to a common ground to lower the screen and a contact closure on a second line to ground to raise it Assumes limit switches set tra...

Страница 5: ...device on time 21 On with On press Off at end of Cool down This is designed to drive a dipper which drops on relay closure and withdraws on relay open This allows full cool down while projector is des...

Страница 6: ...3 Source Key 4 Actioned 44 Source Key 5 Actioned 45 Source Key 6 Actioned 46 Source Key 7 Actioned 47 Source Key 8 Actioned 48 Source Key 9 Actioned Hardware connections to T470 The T470 mounts into s...

Страница 7: ...y connector only option This allows wiring to the screw terminals of power RS232 and IR out PIR in with nothing connected to the CAT5 connector Connection Function Gnd Ground Tx RS232 from T470 to pro...

Страница 8: ...outputs Relays they are actually solid state N FET transistors whose Source is connected to the common Ground of the system and Drain to the output terminal When OFF they are high impedance and when...

Страница 9: ...ion Res Pin must be configured for IR Out Connect IR Emitter as shown below Optional Jed IR Emitter is supplied with 2m of cable this can be extended and has been tested with 50m of CAT6 but care must...

Страница 10: ...T470 Part A User s Manual Jed Micro Pty Ltd Page 10 Mounting bracket for T470...

Отзывы: