1. Before Using the Product
Thank you for purchasing the FD5000 series. This manual should be passed
on to the person who operates the product. Examine the product for dam-
age caused by transportation or any other defects. If you find any damage or
defects, contact the sales agent from which you purchased the product or
Fuji Electric Instruments Co., Ltd.
1.1 Model Codes
The model lineup of the FD5000 series is shown below. Check that the
model code and specifications of your product match those you specified
when ordering.
Instruction Manual for FD5000 Series
1/12
2. Mounting the Product
2.1 Dimensions for Cutting Panel
Cut the panel for mounting according to the following dimensions.
2.2 Mounting the Product to the Panel
To mount the FD5000 to the panel, remove its fittings and insert it through
the hole in the front of the panel. From the back of the panel, fix the
product to the panel with the fittings.
92
+0.8
-0
45
+0.6
-0
70 mm
min.
120 mm min.
Fuji Electric Instruments Co.,Ltd
(UU-33554)
2002.09
Fuji Electric Instruments Co.,Ltd.
International Sales Dept.
No.1,Fuji-machi,Hino-city,Tokyo,191-8502 Japan
Phone +81-42-585-6201,6202
Fax +81-42-585-6187
Instruction Manual for FD5000 Series
UU-33555a 12/12
0: None
Output unit
1: Comparison
2: Analog
3: RS-232C
4: RS-485
5: Comparison and analog
6: Comparison, analog, and RS-232C
Display unit
1: Single display
2: Multi display
Power unit
1: 100 to 240 V AC ± 10%
7: Comparison, analog, and RS-485
F
5 X X X - X X
2: 9 to 60 V DC
D
01: DC voltage measuring unit (range 11: ± 99.99 mV)
Input unit
5 X X X - X X
D
03: DC current measuring unit
02: DC voltage measuring unit
04: AC voltage measuring unit (average rms)
(range 12: ± 999.9 mV ; range 13: ± 9.999 V)
(range 11: 99.99 mV; range 12: 999.9 mV)
05: AC voltage measuring unit (average rms)
(range 14: 99.99 V; range 15: 600 V)
06: AC voltage measuring unit (true rms)
(range 11: 99.99 mV; range 12: 999.9 mV)
07: AC voltage measuring unit (true rms)
(range 14: 99.99 V; range 15: 600 V)
08: AC current measuring unit (average rms)
(range 23: 9.999 mA; range 24: 99.99 mA)
09: AC current measuring unit (average rms)
(range 23: 9.999 mA; range 24: 99.99 mA)
10: AC current measuring unit (true rms)
(range 26: 5 A)
11: AC current measuring unit (true rms)
12: Resistance measuring unit
13: Temperature measuring unit (TC)
14: Temperature measuring unit (RTD)
15: Frequency measuring unit
(inputs: open collector, logic, and magnet)
16: Frequency measuring unit (input: 50 to 500 Vrms)
17: Strain gauze input unit (load cell)
(range 14: ± 99.99 V ; range 15: ± 600 V)
18: Process signal measuring unit
(range 25: ± 999.9 mA)
(range 13: 9.999 V)
(range 13: 9.999 V)
(range 25: 999.9 mA)
(range 25: 999.9 mA)
(range 26: 5 A)
(4 to 20 mA or 1 to 5 V)
(range 23: ± 9.999 mA; range 24: ± 99.99 mA)
MODEL FD5000 SERIES
INSTRUCTION MANUAL
(1) Do not apply a voltage or current exceeding the maximum allowable
value; otherwise, it may damage the equipment.
(2) Use a power voltage within the operation range; otherwise, it may
result in a fire, electrical shock, or malfunction.
(3) The contents of this manual are subject to change without notice.
Although the contents of this manual have been prepared with extra
care, if you have any questions, or find errors or missing
information, contact the sales agent from which you purchased the
product or Fuji Electric Instruments Co.,Ltd.
(4)
After reading this manual thoroughly, keep it in a convenient place
for future reference.
(5)
Caution
!