2-16
Issue 1.0
March 2001
365-575-389
Installation Manual
System Installation Planning
Optical Translator Basics (Continued)
Connecting Non-
OLS-Compatible
Optics to WaveStar
OLS 40G
(continued)
■
The receiver on the customer equipment must operate in the 1550nm band
and meet the input power range and signal-to-noise requirements that the
drop OTU would meet as specified in the Technical Specifications in the
Applications, Ordering, and Planning Guide (APOG, 365-575-386). Not all
receivers from all manufacturers will meet these requirements. Customers
must evaluate the various receivers they wish to directly connect to the
OLS 40G.
■
In the case of fiber congestion relief, if the OLS 40G system is inserted into
a direct fiber span that previously carried the customer signal between
transmitter and receiver, then no drop OTU is needed. In other words, if the
customer equipment operated over the existing span, then it should also
operate through the OLS 40G system using the same span.
■
For OLS 40G systems with more than one span, typically the drop OTU is
required because the fiber dispersion or signal-to-noise performance
exceeds the existing receiver capability.
Signal
Regeneration and
Wavelength
Translation
Optical Translator Units are used between back-to-back OLS end terminals or in
dual facing shelves to regenerate OC-48, OC-12, or OC-3 signals. The
regenerated signal can output the original wavelength or the output can be
translated to another wavelength. See Figure 2-14.
Figure 2-14. OTUs Used for Signal Regeneration and Wavelength Translation
Wavelength Add-
Drop
Optical Translator Units are used to add/drop and regenerate the OC-48, OC-12,
and OC-3 signals between several OLS. The regenerated signals can output the
original wavelength or the output can be translated to another wavelength. See
Figure 2-15.
(Continued on next page)
1A-TX
End Terminal
OTUs For
1A-RCV
End Terminal
Wavelength 3
OTUs For
Wavelength 5
λ
3
λ
3
λ
7
λ
5
To/From
Rest Of
OLS
To/From
Rest Of
OLS
Summary of Contents for WaveStar OLS 40G
Page 4: ......
Page 12: ...Contents xii Issue 1 0 March 2001 365 575 389 Installation Manual...
Page 24: ...Tables xxiv Issue 1 0 March 2001 365 575 389 Installation Manual...
Page 126: ...3 50 Issue 1 0 March 2001 365 575 389 Installation Manual Equipment Installation...
Page 156: ...4 30 Issue 1 0 March 2001 365 575 389 Installation Manual Power Cable Installation...
Page 228: ...5 72 Issue 1 0 March 2001 365 575 389 Installation Manual Wired Cable Installation...
Page 366: ...7 16 Issue 1 0 March 2001 365 575 389 Installation Manual Powering...
Page 436: ...9 46 Issue 1 0 March 2001 365 575 389 Installation Manual Local Installation Testing...
Page 487: ...Issue 1 0 March 2001 12 15 12 Troubleshooting 12 Contents Background 2 Troubleshooting Table 3...
Page 500: ...12 28 Issue 1 0 March 2001 365 575 389 Installation Manual Troubleshooting...
Page 501: ...Issue 1 0 March 2001 A 1 A Releases 1 0 and2 0LBO Selection Tables A Contents Overview 2...
Page 571: ...Issue 1 0 March 2001 H 1 H Optical Protection Switch OPS H Contents Overview 2...