Considerations
The following engineering rules must be applied for the systems mentioned below:
1.
Release 2.0 or higher: For 7 & 8 span applications using LEA7 OAs, place
a 3-dB LBO on the output of each Optical Amplifier except those feeding
the ODUs.
2.
Release 3.0 or higher: For 5 span applications using LEA104 OAs, place
a 3-dB LBO on the output of each Optical Amplifier except those feeding
the ODUs.
3.
Release 2.1 or higher: For 16 wavelength systems, verify the placement of
a 7-dB LBO on the receive OA output (between the OA OUT and the ODU
IN.)
OA Applications
The WaveStar OLS 40G can be configured for many different span and
wavelength combinations. The associated span losses, total reaches, and
allowable number of spans for two-OA and one-OA systems are shown in
Table 10-2 and Table 10-3, respectively.
Table 10-2.
Engineering Rules for Two-OA Systems
(Continued on next page)
OA
Power
Config.
Side
No.
Chan.
No.
Spans
Span Loss
(dB)
Total
Reach
(dB)
Max.
Span
Distance
(km)
Max.
Total
Reach
(km)
Max.
Min.
Max.
LEA104
A
16
1
22
35
35
140
140
2
22
34
68
136
272
3
22
33
99
132
396
B
16
4
26
31
124
124
496
5
26
27
a
150
120
600
a. Each upstream LEA104 must have a 3-dB LOB on its output port.
Summary of Contents for WaveStar OLS 40G
Page 4: ......
Page 12: ...Contents xii Issue 1 0 March 2001 365 575 389 Installation Manual...
Page 24: ...Tables xxiv Issue 1 0 March 2001 365 575 389 Installation Manual...
Page 126: ...3 50 Issue 1 0 March 2001 365 575 389 Installation Manual Equipment Installation...
Page 156: ...4 30 Issue 1 0 March 2001 365 575 389 Installation Manual Power Cable Installation...
Page 228: ...5 72 Issue 1 0 March 2001 365 575 389 Installation Manual Wired Cable Installation...
Page 366: ...7 16 Issue 1 0 March 2001 365 575 389 Installation Manual Powering...
Page 436: ...9 46 Issue 1 0 March 2001 365 575 389 Installation Manual Local Installation Testing...
Page 487: ...Issue 1 0 March 2001 12 15 12 Troubleshooting 12 Contents Background 2 Troubleshooting Table 3...
Page 500: ...12 28 Issue 1 0 March 2001 365 575 389 Installation Manual Troubleshooting...
Page 501: ...Issue 1 0 March 2001 A 1 A Releases 1 0 and2 0LBO Selection Tables A Contents Overview 2...
Page 571: ...Issue 1 0 March 2001 H 1 H Optical Protection Switch OPS H Contents Overview 2...