10-20
Issue 1.0
March 2001
365-575-389
Installation Manual
Fiber Connections
AGNE Office Receive OA Connection
(Continued)
Line 1 Connection
Procedures
Follow the steps in the table below to make Line 1 connections:
Step
Action
Reference
1
The APSD feature must be disabled in order to measure
the OA receive power and select the appropriate
attenuation for the receiving amplifier. Disable the APSD
at this time.
See Danger
above.
2
Clean and then connect the other end of the above
jumper to the LGX location.
3
Select an OA IN LBO based on the measured power and
the number of OC-48 wavelengths (channels) present.
LBO Selection
Procedures.
4
Install the appropriate LBO in 1A OA IN connector if
necessary.
NOTE:
For Single OA applications (no receive OA), there
will be no LBO used on the ODU input. Connect
the LC jumper to the ODU input and proceed to
Step 6.
5
Connect the jumper to the 1A OA IN connector.
Requirement: The 1A OA FAULT LED shall stop
flashing within 1 minute.
6
For single OA applications, place a 5dB LBO in the input
port of the TLM circuit pack in position 1A.
Summary of Contents for WaveStar OLS 40G
Page 4: ......
Page 12: ...Contents xii Issue 1 0 March 2001 365 575 389 Installation Manual...
Page 24: ...Tables xxiv Issue 1 0 March 2001 365 575 389 Installation Manual...
Page 126: ...3 50 Issue 1 0 March 2001 365 575 389 Installation Manual Equipment Installation...
Page 156: ...4 30 Issue 1 0 March 2001 365 575 389 Installation Manual Power Cable Installation...
Page 228: ...5 72 Issue 1 0 March 2001 365 575 389 Installation Manual Wired Cable Installation...
Page 366: ...7 16 Issue 1 0 March 2001 365 575 389 Installation Manual Powering...
Page 436: ...9 46 Issue 1 0 March 2001 365 575 389 Installation Manual Local Installation Testing...
Page 487: ...Issue 1 0 March 2001 12 15 12 Troubleshooting 12 Contents Background 2 Troubleshooting Table 3...
Page 500: ...12 28 Issue 1 0 March 2001 365 575 389 Installation Manual Troubleshooting...
Page 501: ...Issue 1 0 March 2001 A 1 A Releases 1 0 and2 0LBO Selection Tables A Contents Overview 2...
Page 571: ...Issue 1 0 March 2001 H 1 H Optical Protection Switch OPS H Contents Overview 2...