Issue 1.0
March 2001
7-7
365-575-389
Installation Manual
Powering
Powering & Testing Procedures
(Continued)
40G Check Battery
Return Cable
Connection
(continued)
Step
Action
Reference
4
Remove the spade lug terminal from the bottom terminal
of the B (Bottom) Power Filter. The wire color is SLATE/
BLACK and the terminal is labeled -48VR. Using an
Analog Ohmmeter, measure the resistance from the
wire end to the unpainted cabinet frame ground,
NOTE:
Digital Multimeter may cause erroneous readings.
Requirement: The resistance shall measure less than
one (1) ohm.
5
After completing the measurement, restore connection
to the Power Filter. Replace the fuse cover panel and
tighten with the two screws holding the panel in place.
Summary of Contents for WaveStar OLS 40G
Page 4: ......
Page 12: ...Contents xii Issue 1 0 March 2001 365 575 389 Installation Manual...
Page 24: ...Tables xxiv Issue 1 0 March 2001 365 575 389 Installation Manual...
Page 126: ...3 50 Issue 1 0 March 2001 365 575 389 Installation Manual Equipment Installation...
Page 156: ...4 30 Issue 1 0 March 2001 365 575 389 Installation Manual Power Cable Installation...
Page 228: ...5 72 Issue 1 0 March 2001 365 575 389 Installation Manual Wired Cable Installation...
Page 366: ...7 16 Issue 1 0 March 2001 365 575 389 Installation Manual Powering...
Page 436: ...9 46 Issue 1 0 March 2001 365 575 389 Installation Manual Local Installation Testing...
Page 487: ...Issue 1 0 March 2001 12 15 12 Troubleshooting 12 Contents Background 2 Troubleshooting Table 3...
Page 500: ...12 28 Issue 1 0 March 2001 365 575 389 Installation Manual Troubleshooting...
Page 501: ...Issue 1 0 March 2001 A 1 A Releases 1 0 and2 0LBO Selection Tables A Contents Overview 2...
Page 571: ...Issue 1 0 March 2001 H 1 H Optical Protection Switch OPS H Contents Overview 2...