![Rohde & Schwarz NRP2 User Manual Download Page 267](http://html.mh-extra.com/html/rohde-and-schwarz/nrp2/nrp2_user-manual_1477858267.webp)
Remote Control - Commands
NRP2
264
User Manual 1173.9140.02 ─ 07
[SENSe<[1]..4>]:AVERage:COUNt:AUTO
<state>
Can be used to automatically determine a value for the filter legth
[SENSe<[1]..4>]:AVERage:COUNt
. If the automatic switchover is activated with
the ON parameter, the sensor always defines a suitable filter length which can also be
queried via
SENS<[1]..4>:AVER:COUN?
.
Parameters:
<state>
ON | OFF | ONCE
ON
Activates automatic switchover. The sensor always defines a
suitable filter length which can also be queried via
SENS<[1]..4>:AVER:COUN?
OFF
Deactivates automatic switchover.
ONCE
The filter length is automatically detected during the next mea-
surement and set to that value. Thereafter automatic filter length
detection is switched off. The setting can then be queried via
SENS<[1]..4>:AVER:COUN?
*RST:
depending on sensor
[SENSe<[1]..4>]:AVERage:COUNt:AUTO:MTIMe
<mtime>
If the R&S
NRP2 has to determine the filter length automatically, the filter length can
become large and thus also the measurement time.
An upper time limit can be set via
SENS<[1]..4>:AVER:COUN:AUTO:MTIME
(maxi-
mum time). It should never be exceeded. Undesired long measurement times can thus
be prevented (in the
SENS:AVER:COUN:AUTO:TYPE NSR
mode) if the automatic filter
length switchover is on.
Parameters:
<mtime>
float_value, measurement time
Range:
depending on sensor
*RST:
depending on sensor
Default unit: S
[SENSe<[1]..4>]:AVERage:COUNt:AUTO:RESolution
<resolution>
Defines the number of significant places for linear units and the number of decimal pla-
ces for logarithmic units which should be free of noise in the measurement result. This
setting is also performed by the command
on page 245 that tries to set the sensors involved in the measurement
results accordingly. For further details, see
chapter 4, "Instrument Functions"
The setting is only taken into account, if
SENS:AVER:COUN:AUTO:TYPE
is set to
RES
and
SENS:AVER:COUN:AUTO
is
ON
.
SENSe (Sensor Commands)