![Rohde & Schwarz CMU-K20 Operating Manual Download Page 637](http://html.mh-extra.com/html/rohde-and-schwarz/cmu-k20/cmu-k20_operating-manual_1477804637.webp)
CMU-K20/-K21/-K22/-K23/-K24
GSM Signalling Measurements
1115.6088.12 7.5
E-3
FPRINT .............................................................................
CMUGSM: PROC:BSS:LEV:UTIM -102;*OPC?
Absolute power of TCH BS signal, used TS
FPRINT .............................................................................
FPRINT START THE SINGLE SHOT BER (RXQ:BER) AND THE POWER/MODULATION MEASUREMENT
FPRINT THE TX MEASUREMENTS ARE FASTER AND WILL BE FINISHED FIRST
FPRINT WHILE THE RXQ:BER MEAS. IS RUNNING THE RXLEV AND RXQUAL CAN BE QUERIED
FPRINT .............................................................................
CMUGSM: INIT:RXQ:BER;*OPC?
Initiate single shot BER measurement
CMUGSM: INIT:POW:MPR;*OPC?
Initiate combined power/mod. measurement
WHILE CMUGSM: FETC:POW:MPR:STAT? !{} RDY
Wait until power/mod. measurement is in the
RDY
(ready) state, then go to next command
CMUGSM: FETC:POW:MPR?
Return scalar power/mod. results
[MEAS1_1]
IF CMUGSM: FETC:RXQ:BER:STAT? {} RDY GOTO MEAS1_2
Check whether BER measurement is ready
CMUGSM: RREP:RXL?
Return RXLev reported by the mobile
CMUGSM: RREP:RXQ?
Return RXQual reported by the mobile
GOTO MEAS1_1
[MEAS1_2]
CMUGSM: FETC:RXQ:BER?
Read out BER measurement results
To change the traffic channel without dropping the call, use the
PROC:SIGN:CHAN
command. To
change the PCL of the mobile, use
PROC:SIGN:MS:PCL
. To change both parameters simultaneously,
use
PROC:SIGN:CHCC
.
Handover
The example of the last section is repeated for a GSM900/1800 dual-band mobile phone. To this end,
extend your
Winbatch
settings such that
CMUDCS
denotes function group
GSM1800-MS Signalling
.
Repeat and modify the program of the last section in the following way:
!
Before the BCCH signal is generated, set the parameters for call setup and for the measurements
in function group
GSM1800-MS Signalling:
CMUDCS: INP:STAT RF2
Define input connector RF2
CMUDCS: OUTP:STAT RF2
Define output connector RF2
CMUDCS: SENS:CORR:LOSS:INP2 2.0
Define external attenuation to compensate
CMUDCS: SENS:CORR:LOSS:OUTP2 2.0
for known cable losses
CMUDCS: CONF:NETW:SMOD:PCH FAST
Fast power change (over FACCH)
CMUDCS:
CONF:RXQ:CONT:HTIM
0.2,0.0
Reduce holdoff times for AGC and
bit stream synchronization
CMUDCS:
CONF:RXQ:BER1:CONT:LEV:UTIM
-102.0
Absolute level in used timeslot
CMUDCS:
CONF:RXQ:BER1:CONT:LEV:UNT
-20.0
Relative level in unused timeslot
CMUDCS:
CONF:RXQ:BER1
:CONT:REP NONE,NONE
No stop on error
CMUDCS:
CONF:RXQ:BER1
:CONT BER,129
Bit error rate measurement over 129 frames
CMUDCS: CONF:RXQ:BER:TSET T1
Store configuration in test setup 1
CMUDCS: CONF:POW:MPR:CONT SCAL,10
Scalar results, 10 bursts per statistics cycle
CMUDCS: CONF:POW:MPR:CONT:REP SING,NONE,NONE
Single shot measurement, no stop on error
CMUDCS: CONF:BSS:CHAN 512
Channel number of TCH BS signal
CMUDCS: CONF:NETW:POW 5
Power control level of the mobile
setting up a call
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...