![Rohde & Schwarz CMU-K20 Operating Manual Download Page 276](http://html.mh-extra.com/html/rohde-and-schwarz/cmu-k20/cmu-k20_operating-manual_1477804276.webp)
GPRS Signalling and EGPRS
CMU-K20/K21/K22/K23/K24
1115.6088.12 4.198
E-12
Packet Data –
Traffic Channel
The
Packet Data – Traffic Channel
section defines the power control parameter P0
and the traffic channel that the CMU will use for data transfer:
P0
Downlink power control parameter P0; see background
information at the beginning of this section
RF Channel
GSM channel that the CMU will use for packet data transfer
Hopping Sequence
Hopping sequence containing up to 6 channel numbers.
Off
is
used to shorten the hopping sequence. Frequency hopping of
the downlink traffic channel must be enabled explicitly.
Hopping
Enable
(On)
or disable frequency hopping in the downlink
traffic channel.
Reference Level
Reference value for the downlink (BS) signal levels. The
reference level is calculated from the BCCH level of the BS
signal and the downlink power control parameter P0
according to
Reference Level = –85 dBm – P0.
Remote control
CONFigure:BSSignal:PDATa[:TCH]:MSLot:PZERo
CONFigure:BSSignal:PDATa[:TCH]:MSLot:CHANnel
CONFigure:BSSignal:PDATa[:TCH]:MSLot:FHOPping:SEQuence
PROCedure:SIGNalling:PDATa[:TCH]:MSLot:FHOPping:ENABle
[SENSe:]BSSignal:PDATa[:TCH]MSLot:RLEVel?_
The remaining settings are described in section
RF Signals of the MS (Connection Control – MS
Signal)
on p.
4.195
ff. The relationship between the table-oriented
BS Signal
tab and its softkey-
oriented counterpart is analogous the
MS Signal
tab.
Network Parameters (Connection Control – Network)
The
Network
tab defines various parameters of the network that the CMU reports to the mobile station.
The following settings are (E)GPRS-specific and available with option CMU-K42/-K43,
(E)GPRS
Software Extension,
only:
•
Capability of the network:
GSM only
or
GSM + GPRS
or
GSM + EGPRS
(Network Support)
•
The
Main Service
of the mobile:
Circuit Switched
or
Packet Data
•
Routing Area Code
(RAC)
•
GPRS and EGPRS
Coding Scheme
and
Puncturing Scheme
•
Parameters of the GPRS test modes
(PC Meas. Chan., USF, Extend. Dyn. Alloc., Number of PDUs,
Slot Offset, Test Mode with ACK, RLC Mode (Testmode B), Bit Stream)
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...