![Rohde & Schwarz CMU-K20 Operating Manual Download Page 142](http://html.mh-extra.com/html/rohde-and-schwarz/cmu-k20/cmu-k20_operating-manual_1477804142.webp)
Non Signalling: Spectrum Measurements
CMU-K20/K21/K22/K23/K24
1115.6088.12 4.64
E-11
Fig. 4-29 Spectrum Configuration – Limit Lines
Default Settings
The
Default All Settings
switch assigns default values to all settings in the
Limits
tab
(the default values are quoted in the command description in chapter 6 of this
manual). In addition, default switches for the individual spectrum types are
provided.
Remote control
CONFigure:SPECtrum:MODulation[:GMSK]:LIMit:LINE:DEFault
ON|OFF
etc.
Ref. Power
The
Ref. Power
line defines the MS carrier output power domain where the limit
lines are to be determined by linear interpolation (see
Table 4-1
). Below
Min. P.
,
the lower limit line applies, above
Max. P.
, the upper limit line applies. The
Ref.
Power
domain can be modified.
Remote control
CONFigure:SPECtrum:MODulation[:GMSK]:LIMit:LINE
:REFPower[:UPPer]
<Min_Power>,<Max_Power>
Limit Values
The
Limit Values
table section defines upper limits for the power at eleven fixed,
GSM-specific frequency offsets:
Lvl. rel.
Upper limit for the RF power referred to the MS output power
measured in 30 kHz on the carrier. The two values are valid for
output powers below the
Ref. Power
domain
(Min. P.)
and for
output powers above the
Ref. Power
domain
(Max. P.).
Inside
the
Ref. Power
domain,
Lvl. rel.
is determined by linear
interpolation.
Level abs.
Alternative absolute power limits (see
Table 4-2
), applied if the
relative limits
Lvl. rel.
are tighter.
Enable
Switches the limit check at the frequency on and off.
Remote control
CONFigure:SPECtrum:MODulation[:GMSK]:LIMit:LINE
[:ASYMmetrical]:UPPer<nr>
<RelLow>,<RelUpp>,<Abs>,<Enable>
CONFigure:SPECtrum:MODulation[:GMSK]:LIMit:LINE:MODE[:UPPer]
ON|OFF
etc.
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...