CMU-K20/21/22/23/24
Options and Extensions
1115.6088.12 6.215
E-12
PROCedure:SIGNalling:PDATa[:TCH]:MSLot:SCONfig
Slot Configuration: Uplink/Downlink
<Main_TS>,<DL_Enable_0>,..., <DL_Enable_7>, <DL_Power_0>, ..., <DL_Power_7>
<UL_Enable_0>,..., <UL_Enable_7>, <UL_Gamma_0>, ..., <UL_Gamma_7>
<Main_TS>
Description of parameters
Def. value
Def. unit
FW vers.
0 to 7
Main timeslot used for signalling
3
–
V3.10
<DL_Enable_n>
Description of parameters
Def. value
Def. unit
ON | OFF
Enable or disable timeslot no. n
ON (slots 3 and 4)
OFF (other slots)
–
<DL_Power_n>
Description of parameters
Def. value
Def. unit
–127.0 dB to
+127.0 dB
Individual BS level in timeslot no. n:
0.0 (all active DL slots)
dB
<UL_Enable_n>
Description of parameters
Def. value
Def. unit
ON | OFF
Enable or disable timeslot no. n
ON (slot 3)
OFF (other slots)
–
<UL_Gamma_n>
Description of parameters
Def. value
Def. unit
Sig. State
0 to 31
Power control parameter
Γ
CH
in timeslot
no. n
13 (slot 3)
–
CEST
Description of command
This command changes the main timeslot, the levels in all active or inactive timeslots slots of the BS signal and
the channel-specific power control parameters
Γ
CH
that the MS uses in test mode (current values, see
Slot
Configuration Editor
in manual control). This command overwrites the main timeslot defined via
CONFigure:BSSignal:PDATa[:TCH]:MSLot:MTIMeslot
(see p.
6.217)
.
For the DL signal all GSM timeslots are available if the control channel mode is set to BOTC (see command
CONFigure:BSSignal:CCH[:TX]:MODE
on p.
6.186
). Their levels are set individually relative to the
Reference
Level
set via
[SENSe:]BSSignal:PDATa[:TCH]:MSLot:RLEVel
(see p.
6.217
). The DL level range quoted above is
restricted by the condition that the absolute level (calculated from the reference level and the relative individual
levels) must not exceed the level ranges of the RF connectors.
Example:
With output connector RF2 and a reference level of –85 dBm, the individual DL timeslot levels can
be set in the range –52 dB to +75 dB, corresponding to an absolute level of –137 dBm to –10 dBm.
The UL signal settings must be compatible with the capabilities of the MS under test (multislot class, power
class).
PROCedure:SIGNalling:PDATa[:TCH]:MSLot:MS:SCONfig:GAMMa
Change of
Γ
CH
<UL_Gamma_0>, ...,
<UL_Gamma_7>
<UL_Gamma_n>
Description of parameters
Def. value
Def. unit
FW vers.
0 to 31
Power control parameter
Γ
CH
in timeslot
no. n
13 (slot 3)
–
V3.40
Description of command
Sig. State
This command changes the channel-specific power control parameters
Γ
CH
that the MS uses in test
mode (current values, see
Slot Configuration Editor
in manual control).
CEST
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...