CMU-K20/21/22/23/24 Common: MODulation[:PERRor]
1115.6088.12 6.67
E-12
CONFigure:MODulation[:PERRor][:GMSK]:LIMit:UPPer:MODE
<Mode>
Upper Limit Check on/off
<Mode>
Description of parameters
Def. value
Def. unit
FW vers.
ON |
OFF
Upper limit check on
Upper limit check off
ON – V2.00
Description of command
This command switches on or off the tolerance check with respect to the upper limit lines (current and average).
CONFigure:MODulation[:PERRor][:GMSK]:LIMit:LOWer:MODE <Mode>
Lower Limit Check on/off
<Mode>
Description of parameters
Def. value
Def. unit
FW vers.
ON |
OFF
Lower limit check on
Lower limit check off
ON – V2.00
Description of command
This command switches on or off the tolerance check with respect to the lower limit lines (current and average).
CONFigure:MODulation[:PERRor][:GMSK]:LIMit:AVERage
Upper Average Limits
<PhaseErrorPeak>, <PhaseErrorRMS>,<FrequencyError>
Parameter
Description of parameters
Def. value
Def. unit
FW vers.
0.0 to +50.0 deg
0.0 to +50.0 deg
0.0 to +999 Hz
PhaseErrorPeak
PhaseErrorRMS
FrequencyError
+20.0
+5.0
+90
deg
deg
Hz
V1.15
Description of command
This command defines limits for the peak and RMS phase error as well as for the frequency error in the average
trace. The default frequency error is 49 Hz for GSM400, 90 Hz for GSM850 and GSM900, 180 Hz for GSM1800,
190 Hz for GSM1900. Besides, the ranges and default values for the upper and lower
PhaseErrorPeak
and
FrequencyError
limits have equal magnitude but different sign.
CONFigure:MODulation[:PERRor][:GMSK]:LIMit:DEFault
<Enable>
Default
Settings
<Enable>
Description of parameters
Def. value
Def. unit
FW vers.
ON |
OFF
The parameters are set to their default values
Some or all parameters differ from the default values
ON
– V1.15
Description of command
If used as a setting command with the parameter
ON
this command sets all parameters of the subsystem to their
default values (the setting
OFF
causes an error message).
If used as a query the command returns whether all parameters are set to their default values
(ON)
or not
(OFF)
.
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...