CMU-K20/K21/K22/K23/K24
Signalling: Receiver Quality Measurements
1115.6088.12 4.137
E-12
Table 4-8 Definition of RX Level
Value of RX Level
Corresponding signal strength
63
> –48 dBm
62
–49 dBm to –48 dBm
62
–50 dBm to –49 dBm
... ...
2
–109 dBm to –108 dBm
1
–110 dBm to –109 dBm
0
< –110 dBm
Remote
control
[SENSe:]RREPorts:RXLevel?
RX Quality
The output window
RX Quality
indicates the received signal quality determined by
the mobile for the signals of the CMU.
The received signal quality is expressed in terms of dimensionless quality levels
(actually “error levels”) depending linearly on the logarithm of the bit error rate. A
high quality level implies a high bit error rate and thus a
poor
received signal
quality:
Table 4-9 Definition of RX Quality
Value of RX Quality
Bit error rate
0
0% to 0.2%
1
0.2% to 0.4%
2
0.4% to 0.8%
3
0.8% to 1.6%
4
1.6% to 3.2%
5
3.2% to 6.4%
6
6.4% to 12.8%
7
12.8% to 100%
Remote control
[SENSe:]RREPorts:RXQuality?
The receiver reports of up to six neighbor cells of the serving cell can be displayed using the
Neighbor
Cell
hotkey, see page
4.129
.
深圳德标仪器
135-1095-0799
Summary of Contents for CMU-K20
Page 4: ...深圳德标仪器 135 1095 0799 ...
Page 8: ...深圳德标仪器 135 1095 0799 ...
Page 10: ...深圳德标仪器 135 1095 0799 ...
Page 12: ...深圳德标仪器 135 1095 0799 ...
Page 18: ...深圳德标仪器 135 1095 0799 ...
Page 24: ...深圳德标仪器 135 1095 0799 ...
Page 26: ...深圳德标仪器 135 1095 0799 ...
Page 34: ...深圳德标仪器 135 1095 0799 ...
Page 58: ...深圳德标仪器 135 1095 0799 ...
Page 60: ...深圳德标仪器 135 1095 0799 ...
Page 78: ...深圳德标仪器 135 1095 0799 ...
Page 286: ...深圳德标仪器 135 1095 0799 ...
Page 288: ...深圳德标仪器 135 1095 0799 ...
Page 304: ...深圳德标仪器 135 1095 0799 ...
Page 632: ...深圳德标仪器 135 1095 0799 ...